Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel
®
Server
Board S2600WP TPS
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
Power Supply 2
Fan Tachometer
1
(PS2 Fan Tach
1)
A4h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted Non-fatal
As and
De
-
Trig
Offset
M -
Power Supply 2
Fan Tachometer
2
(PS2 Fan Tach
2)
A5h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted Non-fatal
As and
De
-
Trig
Offset
M -
Processor 1
DIMM Aggregate
Thermal Margin
1
(P1 DIMM Thrm
Mrgn1)
B0h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Processor 1
DIMM Aggregate
Thermal Margin
2
(P1 DIMM Thrm
Mrgn2)
B1h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Processor 2
DIMM Aggregate
Thermal Margin
1
(P2 DIMM Thrm
Mrgn1)
B2h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Processor 2
DIMM Aggregate
Thermal Margin
2
(P2 DIMM Thrm
Mrgn2)
B3h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Processor 3
DIMM Aggregate
Thermal Margin
1
(P3 DIMM Thrm
Mrgn1)
B4h
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Intel order number G44057-007 Revision 1.6
190