Technical Product Specification
Appendix B: Integrated BMC Sensor Tables Intel
®
Server
Board S2600WP TPS
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
Processor 4
DTS Thermal
Margin
(P4 DTS Therm
Mgn)
86h All
Temperature
01h
Threshold
01h
–
–
–
Analog R, T A –
Processor2
MSID Mismatch
(P2 MSID
Mismatch)
87h All
Processor
07h
Digital
Discrete
03h
01 – State Asserted fatal
As and
De
–
Trig
Offset
M –
Processor 1
VRD
Temperature
(P1 VRD Hot)
90h All
Temperature
01h
Digital
Discrete
05h
01 – Limit exceeded Non-fatal
As and
De
–
Trig
Offset
M –
Processor 2
VRD
Temperature
(P2 VRD Hot)
91h All
Temperature
01h
Digital
Discrete
05h
01 – Limit exceeded Non-fatal
As and
De
–
Trig
Offset
M –
Processor 3
VRD
Temperature
(P3 VRD Hot)
92h All
Temperature
01h
Digital
Discrete
05h
01 – Limit exceeded Fatal
As and
De
–
Trig
Offset
M –
Processor 4
VRD
Temperature
(P4 VRD Hot)
93h All
Temperature
01h
Digital
Discrete
05h
01 – Limit exceeded Fatal
As and
De
–
Trig
Offset
M –
Processor 1
Memory VRD
Hot 0-1
(P1 Mem01 VRD
Hot)
94h All
Temperature
01h
Digital
Discrete
05h
01 – Limit exceeded Non-fatal
As and
De
–
Trig
Offset
A –
Processor 1
Memory VRD
Hot 2-3
(P1 Mem23 VRD
Hot)
95h All
Temperature
01h
Digital
Discrete
05h
01 – Limit exceeded Non-fatal
As and
De
–
Trig
Offset
A –
Intel order number G44057-007 Revision 1.6