Technical Product Specification
Intel
®
Server
Board S2600WP TPS Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
Processor 2
ERR2 Timeout
(P2 ERR2)
7Dh All
Processor
07h
Digital
Discrete
03h
01 – State Asserted fatal
As and
De
–
Trig
Offset
A –
Processor 3
ERR2 Timeout
(P3 ERR2)
7Eh
Platform-
specific
Processor
07h
Digital
Discrete
03h
01 – State Asserted fatal
As and
De
–
Trig
Offset
A –
Processor 4
ERR2 Timeout
(P4 ERR2)
7Fh
Platform-
specific
Processor
07h
Digital
Discrete
03h
01 – State Asserted fatal
As and
De
–
Trig
Offset
A –
Catastrophic
Error
(CATERR)
80h All
Processor
07h
Digital
Discrete
03h
01 – State Asserted fatal
As and
De
–
Trig
Offset
M –
Processor1
MSID Mismatch
(P1 MSID
Mismatch)
81h All
Processor
07h
Digital
Discrete
03h
01 – State Asserted fatal
As and
De
–
Trig
Offset
M –
Processor
Population Fault
(CPU Missing)
82h All
Processor
07h
Digital
Discrete
03h
01 – State Asserted Fatal
As and
De
–
Trig
Offset
M –
Processor 1
DTS Thermal
Margin
(P1 DTS Therm
Mgn)
83h All
Temperature
01h
Threshold
01h
–
–
–
Analog R, T A –
Processor 2
DTS Thermal
Margin
(P2 DTS Therm
Mgn)
84h All
Temperature
01h
Threshold
01h
–
–
–
Analog R, T A –
Processor 3
DTS Thermal
Margin
(P3 DTS Therm
Mgn)
85h All
Temperature
01h
Threshold
01h
–
–
–
Analog R, T A –
Revision 1.6 Intel order number G44057-007
187