Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel
®
Server
Board S2600WP TPS
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
Processor 2
Thermal Margin
(P2 Therm
Margin)
75h All
Temperature
01h
Threshold
01h
- Analog R, T A
Processor 3
Thermal Margin
(P3 Therm
Margin)
76h
Platform-
specific
Temperature
01h
Threshold
01h
- Analog R, T A
Processor 4
Thermal Margin
(P4 Therm
Margin)
77h
Platform-
specific
Temperature
01h
Threshold
01h
- Analog R, T A
Processor 1
Thermal
Control %
(P1 Therm
Ctrl %)
78h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Processor 2
Thermal
Control %
(P2 Therm
Ctrl %)
79h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Processor 3
Thermal
Control %
(P3 Therm
Ctrl %)
7Ah
Platform-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Processor 4
Thermal
Control %
(P4 Therm
Ctrl %)
7Bh
Platform-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Processor 1
ERR2 Timeout
(P1 ERR2)
7Ch All
Processor
07h
Digital
Discrete
03h
01 State Asserted fatal
As and
De
Trig
Offset
A
Intel order number G44057-007 Revision 1.6
186