Technical Product Specification
Intel
®
Server
Board S2600WP TPS Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
Power Supply 2
Temperature
(PS2
Temperature)
5Dh
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Hard Disk Drive
16 - 24 Status
(HDD 16 - 24
Status)
60h
–
68h
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
6Fh
00 – Drive Presence OK
As and
De
–
Trig
Offset
A
X
01 – Drive Fault Degraded
07 – Rebuild/Remap
in progress
Degraded
69h
-
6Bh
Chassis-
specific
Microcontroller
16h
Discrete 0Ah
04 – transition to Off
Line
Degraded –
Trig
Offset
X
Processor 1
Status
(P1 Status)
70h All
Processor
07h
Sensor
Specific
6Fh
01 – Thermal trip Fatal
As and
De
–
Trig
Offset
M X
07 – Presence OK
Processor 2
Status
(P2 Status)
71h All
Processor
07h
Sensor
Specific
6Fh
01 – Thermal trip
Fatal
As and
De
–
Trig
Offset
M X
07 – Presence OK
Processor 3
Status
(P3 Status)
72h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 – Thermal trip Fatal
As and
De
–
Trig
Offset
M X
07 – Presence
OK
Processor 4
Status
(P4 Status)
73h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 – Thermal trip Fatal
As and
De
–
Trig
Offset
M X
07 – Presence
OK
Processor 1
Thermal Margin
(P1 Therm
Margin)
74h All
Temperature
01h
Threshold
01h
–
–
- Analog R, T A –
Revision 1.6 Intel order number G44057-007