Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel
®
Server
Board S2600WP TPS
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
IO Module
Presence
(IO Mod
Presence)
0Eh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present OK
As and
De
Trig
Offset
M -
SAS Module
Presence
(SAS Mod
Presence)
0Fh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present OK
As and
De
Trig
Offset
M X
BMC Firmware
Health
(BMC FW
Health)
10h All
Mgmt Health
28h
Sensor
Specific
6Fh
04 Sensor Failure
Degraded
As -
Trig
Offset
A X
System Airflow
(System Airflow)
11h All
Other Units
0Bh
Threshold
01h
Analog
FW Update
Status
12h
All
Version
Change 2Bh
OEM defined
x70h
00hUpdate started
01hUpdate
completed
successfully.
02hUpdate failure
OK
As
_
Trig
Offset
A
_
IO Module2
Presence
(IO Mod2
Presence)
13h
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present OK
As and
De
Trig
Offset
M -
Baseboard
Temperature 5
(Platform
Specific)
14h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Baseboard
Temperature 6
(Platform
Specific)
15h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Intel order number G44057-007 Revision 1.6