Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel
®
Server
Board S2600WP TPS
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
07 Redundant:
Transition from non-
redundant state.
Degraded
IPMI Watchdog
(IPMI Watchdog)
03h All
Watchdog 2
23h
Sensor
Specific
6Fh
00 Timer expired,
status only
OK As
Trig
Offset
A X
01 Hard reset
02 Power down
03 Power cycle
08 Timer interrupt
Physical
Security
(Physical Scrty)
04h
Chassis
Intrusion is
chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
04 LAN leash lost
Degraded
OK
As and
De
Trig
Offset
A X
FP Interrupt
(FP NMI Diag
Int)
05h
Chassis -
specific
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 Front panel
NMI/diagnostic
interrupt
OK As
Trig
Offset
A
SMI Timeout
(SMI Timeout)
06h All
SMI Timeout
F3h
Digital
Discrete
03h
01 State asserted
Fatal
As and
De
Trig
Offset
A
System Event
Log
(System Event
Log)
07h
All
Event Logging
Disabled
10h
Sensor
Specific
6Fh
02 Log area
reset/cleared
OK As
Trig
Offset
A X
System Event
(System Event)
08h All
System Event
12h
Sensor
Specific
6Fh
02Undetermined
system H/W failure
04 PEF action
Fatal
OK
As and
De
As
-
Trig
Offset
A X
Button Sensor
(Button)
09h All
Button/Switch
14h
Sensor
Specific
6Fh
00 Power Button
02 Reset Button
OK AS _
Trig
Offset
A X
Intel order number G44057-007 Revision 1.6
178