Technical Product Specification
Connector/Header Locations and Pin-out Intel
®
Server
Board S2600WP TPS
Figure 56. System Status LED (A) and ID LED (B)
Table 70. System Status LED
Color
State
System Status
Description
Green
Solid on
OK
System ready
Green
~1 Hz blink
Degraded
BIOS detected
Unable to use all of the installed memory
(more than one DIMM installed).
1
In a mirrored configuration, when memory
mirroring takes place and system loses
memory redundancy. This is not covered by
(2).
1
PCI Express* correctable link errors.
Integrated BMC detected.
Redundancy loss such as a power supply or
fan. Applies only if the associated platform
subsystem has redundancy capabilities.
CPU disabled – if there are two CPUs and one
CPU is disabled.
Fan alarm – Fan failure. Number of operational
fans should be more than minimum number
needed to cool the system.
Non-critical threshold crossed – Temperature,
voltage, power nozzle, power gauge, and
PROCHOT
2
(Therm Ctrl) sensors.
Battery failure.
Predictive failure when the system has
redundant power supplies.
Intel order number G44057-007 Revision 1.6
148