Technical Product Specification

BIOS Setup Interface Intel®
Server Board S2600WP TPS
Setup Item
Options
Help Text
Comments
FRB-2 Enable
Enabled
Disabled
Fault Resilient Boot (FRB).
The BIOS programs the BMC
watchdog timer for approximately six
minutes. If the BIOS does not
complete POST before the timer
expires, the BMC will reset the
system.
This option controls whether the system
will be reset if the BMC Watchdog
Timer detects what appears to be a
hang during POST. When the BMC
Watchdog Timer is purposed as an
FRB-2 timer, it is initially set to allow six
minutes for POST to complete.
OS Boot
Watchdog
Timer
Enabled
Disabled
The BIOS programs the watchdog
timer with the timeout value
selected. If the OS does not
complete booting before the timer
expires, the BMC will reset the
system and an error will be logged.
Requires OS support or Intel
Management Software Support.
This option controls whether the system
will set the BMC Watchdog to detect an
apparent hang during OS boot. The
BIOS sets the timer before starting the
OS bootstrap load procedure. If the OS
Load Watchdog Timer times out, then
presumably the OS failed to boot
properly.
OS Boot
Watchdog
Timer Policy
Power Off
Reset
If the OS boot watchdog timer is
enabled, this is the system action
taken if the watchdog timer expires.
[Reset]System performs a reset.
[Power Off]System powers off.
This option is grayed out and
unavailable when the O/S Boot
Watchdog Timer is disabled.
OS Boot
Watchdog
Timer Timeout
5 minutes
10 minutes
15 minutes
20 minutes
If the OS watchdog timer is enabled,
this is the timeout value BIOS will
use to configure the watchdog timer.
This option is grayed out and
unavailable when the O/S Boot
Watchdog Timer is disabled.
Plug and Play
BMC Detection
Enabled
Disabled
If enabled, the BMC will be
detectable by OSes that support
plug and play loading of an IPMI
driver. Do not enable this option if
your OS does not support this
driver.
This option controls whether the OS
Server Management Software will be
able to find the BMC and automatically
load the correct IPMI support software
for it. If your OS does not support Plug
& Play for the BMC, you will not have
the correct IPMI driver software loaded.
Console
Redirection
View/Configure console redirection
information and settings.
Takes the user to the Console
Redirection screen.
System
Information
View system information.
Takes the user to the System
Information screen.
BMC LAN
Configuration
View/Configure BMC LAN channel
and user settings.
Takes the user to the BMC
configuration screen.
Intel order number G44057-007 Revision 1.6
118