Technical Product Specification

Intel®
Server Board S2600WP TPS BIOS Setup Interface
5.4.2.8
Mass Storage Controller Configuration
The Mass Storage Configuration screen allows the user to configure the Mass Storage
controllers that are integrated into the server board on which the BIOS is executing. This
includes only onboard Mass Storage controllers. Mass Storage controllers on add-in cards are
not included in this screen, nor are other storage mechanisms such as USB-attached storage
devices or Network Attached Storage.
There are two types of onboard controller configured in this screen, the AHCI SATA controller
and the Storage Control Unit (SCU) with SATA or SAS drive support and RAID support. There
are also informational displays of AHCI and SCU controller configuration, and SATA Drive
Information when applicable. If the presence of an Intel
®
Storage Module is detected, the type of
Storage Module is displayed as information-only.
To access this screen from the Main screen, select Advanced > Mass Storage Controller
Configuration. To move to another screen, press the <Esc> key to return to the Advanced
screen, then select the desired screen.
Advanced
Mass Storage Controller Configuration
AHCI Controller Configuration <AHCI Port Configuration>
SATA/SAS Controller Configuration <SCU SAS/SATA Port Configuration>
AHCI Capable SATA Controller Disabled/Compatibility/Enhanced/
AHCI
/RAID Mode
AHCI HDD Staggered Spin-Up Enabled/
Disabled
SAS/SATA Capable Controller Disabled / INTEL(R) ESRT2 (LSI*) /
INTEL(R) RSTe
Intel(R) Storage Module
- None / <Name of storage module detected >
PCI Express Gen3
Enabled
/Disabled
SATA Port 0
Not Installed / <Drive Information>
SATA Port 1
Not Installed / <Drive Information>
SATA Port 2
Not Installed / <Drive Information>
SATA Port 3
Not Installed / <Drive Information>
SATA Port 4
Not Installed / <Drive Information>
SATA Port 5
Not Installed / <Drive Information>
Figure 29. Mass Storage Controller Configuration Screen
Revision 1.6 Intel order number G44057-007 95