Technical Product Specification

Product Overview Intel
®
Server System H2000WP Family TPS
Chipset Temperature Sensor
4, 6
On-board Ethernet Controller Temperature Sensors
4, 6
Add-In Intel
®
SAS/IO Module Temperature Sensors
4, 6
Power Supply Thermal Sensor
4, 9
Processor VR Temperature Sensors
4, 7
DIMM VR Temperature Sensors
4, 7
BMC Temperature Sensor
4, 7
Global Aggregate Thermal Margin Sensors
8
Notes:
1. For fan speed control in Intel
®
chassis
2. For fan speed control in third party chassis
3. Temperature margin from throttling threshold
4. Absolute temperature
5. PECI value or margin value
6. On-die sensor
7. On-board sensor
8. Virtual sensor
9. Available only when PSU has PMBus*
The following diagram illustrates the fan speed control structure:
Figure 3. Fan Speed Control Structure
2.4 Hard Drive and Peripheral Bays
Table 7. Intel
®
Server System H2312WP and H2216WP Drive Support Matrix
Intel
®
Server System H2312WP
Intel
®
Server System H2216WP
Slim-line SATA Optical Drive
Not Supported
Not Supported
Internal USB Floppy Drive
Not Supported
Not Supported
SATA/SAS Hard Disk Drives (3.5")
Up to Twelve
Not Supported
SATA/SAS Hard Disk Drives (2.5")
Not Supported
Up to Sixteen
SATA DOM
Support
Support
Intel order number: G52418-006 Revision 1.6
12