Table 4. Chassis Dimension (SKU: H2216WPJR)
Height 87.9mm 3.46"
Width
438mm
17.24"
Depth 733mm 28.86"
Weight
Chassis – basic configured (2 PSU, 0 drives)
Chassis – fully configured (2 PSU, 16 drives)
Kg.
29
32
Lbs.
63.93
70.55
2.3 System Level Environmental Limits
The following table defines the Intel
®
Server Board S2600WP operating and non-operating
environmental limits. Operation of the Intel
®
Server Board S2600WP at conditions beyond those
shown in the following table may cause permanent damage to the system. Exposure to absolute
maximum rating conditions for extended periods may affect system reliability.
Table 5. System Environmental Limits Summary
Parameter
Limits
Temperature
Operating
ASHRAE Class A2 – Continuous Operation. 10ºC to 35ºC (50ºF to 95ºF) with the
maximum rate of change not to exceed 10ºC per hour
ASHRAE Class A3 – Includes operation up to 40ºC for up to 900 hrs. per year.
ASHRAE Class A4 – Includes operation up to 45ºC for up to 90 hrs. per year.
Shipping -40ºC to 70ºC (-40ºF to 158ºF)
Humidity
Non-Operating 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures
from 25°C to 35°C)
Shock
Operating Half sine, 2g, 11 mSec
Unpackaged Trapezoidal, 25g, velocity change is based on packaged weight
Packaged Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged 5 Hz to 500 Hz 2.20 g RMS random
Packaged 5 Hz to 500 Hz 1.09 g RMS random
AC-DC
Voltage 90V to 132V and 180V to 264
Frequency 47Hz to 63Hz
Source
Interrupt
No loss of data for power line drop-out of 12 mSec
Surge Non-
operating and
operating
Unidirectional
Line to earth
Only
AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Intel order number: G52418-006 Revision 1.6
6