Specification Update
Enterprise Platforms and Services Marketing Monthly Specification Update
9
12. Integrated BMC Web Console – Power Statistics page –
Minimum wattage reads as zero
Problem On some systems the Integrated BMC Web Console Power Statistic page may
display the Minimun wattage as zero (0W) after the system has been powered.
This reading will stay at zero until the next power cycle of the system.
Implication This is an incorrect reading only and does not affect operation.
Status This issue was fixed in BMC 1.10.r3560 release.
Workaround None.
13. Integrated BMC Web Console – Power Control page – Perform
Action button not functional
Problem After performing a Graceful shutdown from the Integrated BMC Web Console
Power Control page the Perform Action button is greyed out and cannot be
pressed to request another action.
Implication You cannot perform a power on of the system.
Status This issue was fixed in BMC 1.10.r3560 release.
Workaround Select another page in the Integrated BMC Web Console and then return to the
Power Control Page. The Perform Action button will then be available.
14. IPMI Get Chassis Status command returns incorrect Chassis
Identify State
Problem When a Get Chassis Status command is issued, after the Chassis Identify LED
has been forced on, the status of off (00b) is returned for Chassis Identify State
(response data byte 4 – bits [5:4]).
Implication Unable to correctly read when the Chassis Identify LED is on.
Status This issue was fixed in BMC 1.10.r3560 release.
Workaround None.