Service Guide
Hardware Installations and Upgrades
50 Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR Service Guide
Removing and Installing 8x3.5” Hot-swap Hard Drive
Cage Assembly
/
NOTE
This procedure applies only to the Intel
®
Server System P4000IP family with 8x3.5” hot-swap hard disk
drive cage configuration.
Removing 8x3.5” Hot-swap Hard Drive Cage Assembly
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel (Pedestal
Only)”.
5. Disconnect the power and data cables to the backplane.
6. Use screwdriver to release the hot-swap hard drive cage (see letter A) from the chassis and remove
the hot-swap hard drive cage (see letter B).
Figure 64. Removing the 8x3.5” Hot-swap HDD Cage Assembly