6. Remove system fan by pushing the tabs outward and disengaging from its snap-in bracket (see letter
B).
Figure 45. Removing fixed system fan from chassis
Installing the Fixed Fan
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the air duct if the air duct is installed. For instructions, see the Quick Start Users Guide or
Service Guide provided with your Intel
®
server/workstation board.
5. Insert the fan cable in the fan bracket as shown in figure below (see letter A). Pay attention to the fan
cable connector color. The fan with blue fan cable connector should be installed in fan 2 bracket; the
fan with white fan connector should be installed in fan 1 bracket.
Figure 46. Inserting the fan cable in the corresponding fan bracket