Removing Memory
1. Locate the DIMM sockets. Gently spread the retaining clips at each end of the socket. The DIMM lifts from
the socket.
2. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package.
Replacing a Server/Workstation Board
/
NOTE
The server/workstation board you can install in your chassis depends upon the chassis model.
To install or remove a server board, do the following:
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel assembly if it is installed. For instructions, see “Removing the Bezel
Assembly (Pedestal Only)”.
5. Remove any PCI add-in boards that are present. For instructions, see “Removing PCI Add-in
Board(s)”.
6. If installing a server board, refer to the Service Guide and/or Quick Start User’s Guide that shipped
with your Intel
®
server/workstation board for installation instructions. Use the mounting screws,
bumpers and standoffs (if necessary) that came with your chassis to secure the server/workstation
board to the chassis. Make sure the server/workstation board is properly seated and then tighten the
screws firmly, starting with the screws at the center of the server/workstation board. Make cable
connections per instructions in the Intel
®
server/workstation board Service Guide and/or Quick Start
User’s Guide.
7. If removing a server board, disconnect all cables connected to the server board.
8. Remove the mounting screws, starting with the screws at the center of the server/workstation board.
Remove the server board.
9. If desired, install any PCI Add-in boards. For instructions, see “Installing PCI Addin Board(s)”.
10. Re-install the front bezel assembly. For instructions, see “Installing the Front Bezel (Pedestal Only)”.
11. Re-install the chassis cover. For instructions, see “Installing the Chassis Cover”.
12. Plug all peripheral devices and the AC power cable into the server.
13. Power up the server.