System Environmental Limits
Table 19. System Environmental Limits
Parameter
Limits
Temperature
Operating
10ºC to 35ºC
1
(50ºF to 95ºF) with the maximum rate of change not to
exceed 10°C per hour
Non-Operating -40ºC to 70ºC (-40ºF to 158ºF)
Humidity
Non-Operating 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at
temperatures from 25°C to 35°C)
Shock
Operating Half sine, 2g, 11 mSec
Unpackaged Trapezoidal, 25g, velocity change is based on packaged weight
Packaged Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged 5 Hz to 500 Hz 2.20 g RMS random
Packaged 5 Hz to 500 Hz 1.09 g RMS random
AC-DC
Voltage 90 Hz to 132 V and 180 V to 264 V
Frequency 47 Hz to 63 Hz
Source Interrupt No loss of data for power line drop-out of 12 mSec
Surge Non-
operating and
operating
Unidirectional
Line to earth Only AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Air Discharged 12.0 kV
Contact Discharge 8.0 kV