Service Guide

BIOS Setup Utilities
Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR Service Guide 185
Option Values: <ME FW Rev display>
Help Text: <None>
Comments: Information only.
10. SDR Revision
Option Values: <SDR Rev display>
Help Text: <None>
Comments: Information only.
11. UUID
Option Values: <UUID display>
Help Text: <None>
Comments: Information only.
BMC LAN Configuration
To access this screen from the Main screen, select Server Management > System Information. To
move to another screen, press the <Esc> key to return to the Server Management screen, then
select the desired screen.
The BMC configuration screen allows the user to configure the BMC Baseboard LAN channel and
an Intel
®
RMM4 LAN channel, and to manage BMC User settings for up to five BMC Users.
An Intel
®
RMM4 Management Module may be installed in the server system.
If the Management Module is installed, it may also have a Dedicated Server Management NIC
Module (DMN) installed with it. In that case, the LAN settings for the Intel
®
RMM4 with Dedicated
Server Management NIC may be configured.
When there is no Management Module installed in the system, or there is an Intel
®
RMM4-Lite
without a DMN installed, the LAN settings specific to the Intel
®
RMM4 are grayed out and not
available.
This screen has a choice of IPv4 or IPv6 addressing. When IPv6 is disabled, only the IPv4
addressing options appear. When IPv6 is enabled, the IPv4 options are grayed out and unavailable,
and there is an additional section active for IPv6-addressing. This is true for both the Baseboard
LAN configuration and the Intel
®
RMM4 with Dedicated Server Management NIC Module.
IP addresses for either IPv4 or IPv6 addressing can be assigned by static IP addresses manually
typed in, or by dynamic IP addresses supplied by a Dynamic Host Configuration Protocol (DHCP)
server. IPv6 addressing can also be provided by “stateless autoconfiguration” which does not
require a DHCP server.