Service Guide

BIOS Setup Utilities
Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR Service Guide 137
Option Values: <AHCI Port Configuration>
One of these strings:
Controller is disabled
2 ports of 6Gb/s SATA
2 ports of 6Gb/s SATA & 4 ports of 3Gb/s SATA
Help Text: <None>
Comments: Information only. This is a display showing which ports are available
through the onboard AHCI capable SATA controller, if the controller is enabled.
This information is also displayed during POST in the POST Diagnostic Screen.
The number of SATA ports available from the integrated AHCI-capable SATA Controller is
dependent on the specific server board installed in the system. Different server board
designs expose different SATA port configurations. The Platform ID (Board ID) is displayed in
the Main Screen
2. SATA/SAS Controller Configuration
Option Values: <SCU SAS/SATA Port Configuration>
One of these strings:
Controller is disabled
4 ports in SATA mode
4 ports in SAS mode
8 ports in SATA mode
8 ports in SAS mode
Help Text: <None>
Comments: Information only. This is a display showing the number of ports which
are available through the SCU controller, and whether they are configured for SATA or SAS.
This information is also displayed during POST in the POST Diagnostic Screen.
Various SATA/SAS Capable Controller configurations require the installation of Intel
®
RAID
C600 Upgrade Keys:
4 port SATA requires no key or AXXRKSATA4R5 key
4 port SAS requires AXXRKSAS4 or AXXRKSAS4R5 key
8 port SATA requires AXXRKSATA8 or AXXRKSATA8R5 key
8 port SAS requires AXXRKSAS8 or AXXRKSAS8R5 key
3. AHCI Capable SATA Controller