Technical Product Specification
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-004 Revision 1.4
128
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
BMC Firmware
Health
(BMC FW Health)
10h
All
Mgmt Health
28h
Sensor
Specific
6Fh
04 – Sensor Failure
Degraded
As
-
Trig
Offset
A
X
System Airflow
(System Airflow)
11h
All
Other Units
0Bh
Threshold
01h
–
–
–
Analog
–
–
–
FW Update Status
12h
All
Version
Change 2Bh
OEM defined
x70h
00hUpdate started
01hUpdate
completed
successfully.
02hUpdate failure
OK
As
_
Trig
Offset
A
_
IO Module2
Presence
(IO Mod2
Presence)
13h
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present
OK
As and
De
–
Trig
Offset
M
-
Baseboard
Temperature 5
(Platform Specific)
14h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard
Temperature 6
(Platform Specific)
15h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
IO Module2
Temperature
(I/O Mod2 Temp)
16h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
PCI Riser 3
Temperature
(PCI Riser 5 Temp)
17h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X