Technical Product Specification

Appendix C: Integrated BMC Sensor Tables Intel® Server Board S2600CO Family TPS
Revision 1.6
Intel order number G42278-004
124
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/
Reading
Type
Event Offset Triggers
Contrib. To
System Status
Assert/
De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
(Fan Redundancy)
specific
04h
0Bh
01 - Redundancy lost
Degraded
and
De
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal
06 Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from non-
redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh
All
Temperature
01h
Digital
Discrete
03h
01 State Asserted
Fatal
As
and
De
Trig Offset
M
X
IO Module Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Boar
d
15h
Digital
Discrete
08h
01 Inserted/Present
OK
As
and
De
Trig Offset
M
X
SAS Module Presence
(SAS Mod Presence)
0Fh
Platform-
specific
Module/Boar
d
15h
Digital
Discrete
08h
01 Inserted/Present
OK
As
and
De
Trig Offset
M
X
BMC Firmware Health
(BMC FW Health)
10h
All
Mgmt Health
28h
Sensor
Specific
6Fh
04 Sensor Failure
Degraded
As
-
Trig Offset
A
X
System Airflow
(System Airflow)
11h
All
Other Units
0Bh
Threshold
01h
Analog