Technical Product Specification
On-board Connector/Header Overview Intel® Server Board S2600CO Family TPS
Revision 1.6
Intel order number G42278-004
88
8.3.1 SATA Only Connectors: 6 Gbps
The server board includes two white single port SATA only connectors capable of transfer rates
of up to 6Gb/s. On the server board these connectors are labeled as SATA_0 and SATA_1. The
following table provides the pin-out for both connectors.
Table 32. SATA Only Connector Pin-out (SATA_0 and SATA_1)
Pin
Signal Name
1
GND
2
SATA_TX_P
3
SATA_TX_N
4
GND
5
SATA_RX_N
6
SATA_RX_P
7
GND
Note: As an option, SATA_0 supports vertical, high profile SATA_DOM.
8.3.2 SATA/SAS Connectors
The server board includes eight SATA/SAS connectors. On the server board, these connectors
are labeled as SATA/SAS_ 0 to SATA/SAS_7. By default, only the connector labeled
SATA/SAS_0 to SATA/SAS_3 are enabled and has support for up to four SATA ports capable
of transfer rates of up to 3Gb/s. The connector labeled SATA/SAS_4 to SATA/SAS_7 is only
enabled when an optional Intel
®
RAID C600 Upgrade Key is installed. See Table 10 for a
complete list of supported storage upgrade keys. The following tables provide the pin-out for
each connector.
Table 33. SATA/SAS Connector Pin-out (SATA/SAS_0 to SATA/SAS_7)
Pin
Signal Name
1
GND
2
SATA_TX_P
3
SATA_TX_N
4
GND
5
SATA_RX_N
6
SATA_RX_P
7
GND
8.3.3 SAS SGPIO Connectors
Table 34. SAS SGPIO Connector Pin-out (SAS_SPGIO_0 and SAS_SPGIO_1)
Pin
Signal Name
Pin#
Signal Name
1
CLOCK
2
LOAD
3
GND
4
DATAOUT
5
DATAIN
8.3.4 Intel
®
RAID C600 Upgrade Key Connector
The server board provides one connector to support Intel
®
RAID C600 Upgrade Key. The Intel
®
RAID C600 Upgrade Key is a small PCB board that enables different versions of RAID 5
software stack and/or upgrade from SATA to SAS storage functionality. On the server board,
the connector is labeled as STOR_UPG_KEY. The pin configuration of connector is identical
and defined in the following table.