Qsug
17
Software
• BIOS, Drivers, and Operating System Installation
A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS
Setup Utility to determine the installed BIOS version. Compare this to the versions at:
http://www.intel.com/support/motherboards/server.
If new versions are available, update the BIOS on your server. See the Techinical Product Specification
on the Intel
®
Server Deployment Toolkit CD for update instructions.
B. Configure your RAID Controller:
Use the instructions provided with the RAID controller.
C. Install your Operating System:
Use the instructions provided with the RAID controller
and with the operating system.
D. Install Operating System Drivers: With the operating system running, insert the
Intel
®
Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel
®
Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other
operating systems, browse the CD folders to locate and install the driver files.
Side 2
STOR_UPG_KEY
10
Locate the white-colored four-pin key header near DIMM_C1 slot.
Match the Key and connector orientation and press down to install.
15
Install Add-in
Card[s]
See the documentation that came with your
server chassis for add-in card installation.
For the Intel
®
Server Chassis P4000M
series, see the Quick Installation User's
Guide accompanying the chassis.
14
Install Optional
Components
Follow the Intel
®
Trusted Platform Module Hardware
User’s Guide to install the TPM module.
Follow Intel
®
Remote Management Module 4 User
GUide to install RMM4 modules.
Follow the instructions come along with the eUSB SSD
device to install eUSB SSD.
16
Finishing Up
CAUTION: See your chassis
documentation for AC power and
grounding requirements.
Network
USB 0
USB 1
USB 2
USB 3
NIC1
10/100/
1000 Mb
NIC2
10/100/
1000 Mb
NIC3
10/100/
1000 Mb
NIC4
10/100/
1000 Mb
Video
Serial A
Before installing your operating
system, you must finish your chassis
installation, make I/O connections and
plug in AC power.
See your chassis documentation for AC
power and grounding requirements.
Common Problems and Solutions
The system does not boot or show video at power-on.
•
Check that the +12V CPU power connector is plugged in. Without this cable, the processors will not have any power.
•
Only Intel
®
Xeon
®
Processor E5-2600 series
with 135 W and less Thermal Design Power (TDP) are supported on S2600CO4.
Previous generation Intel
®
Xeon
®
processors are not supported.
•
Only Intel
®
Xeon
®
Processor E5-2600 series
with 150 W and less Thermal Design Power (TDP) are supported on S2600COE.
Previous generation Intel
®
Xeon
®
processors are not supported.
Beep code 1-5-2-1 in a system means you do not have Intel
®
Xeon
®
Processor E5-2600 series
installed.
•
The system generates the memory error beep code and POST diagnostic LED message {0XE0~0XEF} that indicates memory errors in early POST.
•
Remember, all DIMMs must be:
•
DDR3 800/1066/1333/1600 MHz ECC UDIMM/RDIMM/LRDIMM.
•
From the same manufacturer.
•
Installed beginning with DIMM A1.
For a list of hardware components that have been tested with
this system, see:
http://www.intel.com/support/motherboards/server
CPU 1 Socket
CPU 2 Socket
Main Power
Connector Detail
C
Latch
Tab
CPU Power
Connector Detail
B
A
8
Make Server Board
Power Connections
Attach the CPU 1 power connector.
Attach the CPU 2 power connector.
CAUTION:
Note the location of the
latch on each power cable
connector and align it with the matching
tab on each server board socket.
A
B
Attach the main power connector.
C
IMPORTANT NOTE:
If you are using a
non-Intel server chassis with an ATX
power supply, see the documentation
that came with your chassis for
installation information.
Server
Board
SAS/SATA 0
SAS/SATA 1
SAS/SATA 2
SAS/SATA 3
SAS/SATA 4*
SAS/SATA 5*
SAS/SATA 6*
SAS/SATA 7*
SATA 1**
SATA 0**
11
Connect Hard Drives/Optical Drive to
Server Board
Connect SAS/SATA Data Cables to server board here.
NOTE:
* SATA/SAS functionality on ports 0-7 requires
purchase of an optional Intel
®
RAID C600
Upgrade Key.
** 6Gb/s SATA port.
Server
Board
System Fan 1-6
Connector
Detail
System Fan 7
Connector
Detail
13
Chassis Fan Connections
For a non-Intel server chassis, see the documentation accompanying your chassis for specific chassis
fan connection requirements. Refer to the "Making Connections to the Server Board - Quick Reference"
section below.
CPU 1 Socket
CPU 2 Socket
C1DIMM C2 D1 D2
B2DIMM B1 A2 A1
E1DIMM E2 F1 F2
H2DIMM H1 G2 G1
Memory Configurations and Population Order:
Note: For additional memory configurations, see the
Techinical Product Specification for Intel
®
Server
Board S2600CO at:
http://www.intel.com/support/motherboards/server.
Memory sizing and configuration is supported only for
qualified DIMMs approved by Intel
®
. For a list of
supported memory, see the tested memory list at
http://serverconfigurator.intel.com/default.aspx
Memory Type: Minimum of one 1 GB,
DDR3 800/1066/1333/1600 MHz
ECC UDIMM/RDIMM/LRDIMM.
7
Install DIMM Memory Modules
DDR3 DIMM Memory Identification:
DIMM
notch and
socket
bump must
be aligned as
shown.
Other
Memory
DDR3
This server board supports up to 16 DDR3 1066/1333/1666 ECC
UDIMM/RDIMM/LRDIMM.
CAUTION: Observe normal ESD (ElectroStatic Discharge) procedures
to avoid possible damage to system components.
Install Optical
Drive and
Hard Drive(s)
See the documentation that came
with your server chassis for drive
installation.
9
Making Connections to the Server Board — Quick Reference
Internal
USB
Connector
Detail
USB
USB
USB
Connector
Detail
Front Panel
Front Panel
Connector
Detail
12
Attach Front Panel, and USB Connections
Note: For a non-Intel
chassis, see your
chassis documentation
for front panel features
and server board
connection requirements.
Install Intel® RAID C600
Upgrade Key (Optional)
=
Make this connection to the P4000M series
chassis with fixed system fan configuration.
=
Make this connection to the P4000M series chassis
with hotswap fans, backplane(s), power supply(s)
=
Make this connection when applicable
= Make this connection
Intel
®
Server Chassis
P4000M series
A. CPU 1-2 Power Connector
B. Main Power Connector
C. Front Panel Header
Required Connections
Intel
®
Server Chassis
P4000M series
Optional Connections
D. System Fan 1 Header
E. System Fan 2 Header
F. System Fan 3 Header
G. System Fan 4 Header
H. System Fan 5 Header
I. System Fan 6 Header
J. System Fan 7 Header
K. CPU 1 Fan Header
L. CPU 2 Fan Header
M. Serial B
N. Storage Upgrade Key
O. USB 5/6 (Front Panel)
P. IPMB
Q. SAS/SATA Connectors
R. SATA 6G
S. RMM4 Lite
T. Chassis Intrusion
U. RMM4 NIC
V. HSBP_I
2
C
W. SAS SGPIO
X. eUSB SSD
Y. TPM
Z. USB 4 (Type A)
AA. LCP
AB. PMBus
AC. FAN BOARD_I
2
C
AD. IEEE_1394B
IMPORTANT Note:
Cables should be
tied for better airflow.
Use cable-ties compulsorily.
Note: For a non-Intel Chassis, see your chassis documentation for server board
connection information.
Note: All optional connections are not shown in this diagram. Refer to your
Server Board Service Guide, and your server chassis documentation for
additional connection information.
Cable Routing in Intel
®
Server Chassis P4000M series with
Fixed Fans, Fixed HDDs, Fixed PSU
Description
A. CPU1/CPU2 Power Cable
B. Server Board Main Power Cable
(Power extend cable is needed)
C. Fixed HDD Power Cable
D. ODD Power Cable
E. Front Panel Cable, USB Cable
F. ODD Data Cable (Connect To White
SATA 6G Connectors On Server Board)
Description
G. Fixed HDD Data Cable
H. System FAN 1
I. System FAN 2
J. IEEE_1394B cable (Optional, Connect to
RMM4/IEEE_1394B connector on P4000M
chassis back panel)
AE. Optional 12V Power
DIMM E1
DIMM E2
DIMM F1
DIMM F2
DIMM H2
DIMM H1
DIMM G2
DIMM G1
DIMM B2
DIMM B1
DIMM A2
DIMM A1
DIMM C1
DIMM C2
DIMM D1
DIMM D2
FAN BOARD_I
2
C
(Intel
®
Server Board
S2600CO4 only)
C
Front Panel
Chassis Intrusion
T
RMM4 Lite
S
CPU 2 Fan
L
Sys Fan 7
J
CPU 2 Power
A
Serial B
M
RMM4 NIC
U
USB 5/6
O
Storage Upgrade Key
N
CPU 1 Power
A
H
I
GF
Sys Fan 4
D
Sys Fan 6
E
Sys Fan 5
SAS SGPIO
W
Sys Fan 2
Sys Fan 1
Sys Fan 3
IPMB
P
HSBP_I
2
C
V
1
0
1
0
SAS/SATA
Q
SATA
R1
Main Power
B
USB 4
Z
PMBus
AB
Optional 12V Power
AE
LCP
AA
TPM
Y
eUSB SSD
X
CPU 1 Fan
K
AC
IEEE_1394B
(Intel
®
Server Board
S2600COE only)
AD
Cable Routing in Intel
®
Server Chassis P4000M series with Hotswap
Fans, backplane(s), redundant PSU(s)
Server Board
Power
Supply
CPU2 CPU1
Main Power
Front
Panel
SAS/
SATA
USB
1394B
E
B
A
D
C
F
G
FAN_2
FAN_1
H
I
J
Server Board
Power Supply
CPU2 CPU1
Main Power
Front
Panel
SAS/
SATA
SGPIO
HSBP_I
2
C
USB
1394B
A
D
C
I
J
G
E
F
PMBus
FAN_3
FAN_4
FAN_5
FAN_2
FAN_1
K
L
M
N
O
B
P
H
I. HSBP_I
2
C Cable (5pin to 3pin, provide connection
from hot-swap back plane to server board )
J. HSBP_I
2
C Cable (5pin to 5pin, only for the chassis
with 2 hot-swap back plane cascade)
K. System FAN 1 L. System FAN 2
M. System FAN 3 N. System FAN 4
O. System FAN 5
P. IEEE_1394B cable (Optional, Connect to RMM4/IEEE_1394B
connector on P4000M chassis back panel)
Description Description
A. CPU1/CPU2 Power Cable
B. Server Board Main Power Cable (Power extend cable is needed)
C. Backplane Power Cable
D. ODD Power Cable
E. Front Panel Cable, USB Cable
F. ODD Data Cable (Connect To White SATA 6G Connectors
On Server Board)
G. Hotswap HDD Data Cable and SGPIO
H. PMBus Cable