User Guide

22 Intel
®
System Configuration Utility User Guide
are valid
but
syscfg /bbo HDD 3 2 1 NW 2 1
is not a valid command.
4.3.5 Configure BIOS Settings (/bcs)
syscfg /bcs [BIOS_Group_Name] BIOS_Setting_Name Value [BIOS_Setting_Name Value […] ]
On S1400/S1600/S2400/S2600/S4600 platform series the command is
syscfg /bcs [BIOS administrator password] [BIOS_Group_Name] BIOS_Setting_Name Value
[BIOS_Setting_Name Value […] ]
BIOS_Setting_Name
The name of the BIOS settings on the BIOS
Setup screen. Refer to the Technical
Product Specification for your server board
for the BIOS Setup setting names.
BIOS_Group_Name
The name of the page in the BIOS Setup
screen. Refer to the Technical Product
Specification for your server board for the
BIOS Setup screen names.
Value
The value for the BIOS Setting.
Set the value of individual BIOS Settings.
Refer to the Technical Product Specification for your Intel
®
Server Board for more
information on BIOS Setup options.
Examples:
syscfg /bcs “Quiet Boot” 0
syscfg /bcs “Main” “Quiet Boot” 0 “POST Error Pause” 1
syscfg /bcs “system acoustic and performance configuration” “Set throttling mode” 2
“Altitude” 900 “Set fan profile” 2
On S1400/S1600/S2400/S2600/S4600 platform series.
1. When BIOS administrator password is set and it value is “admin@123”
syscfg /bcs “admin@123” “Quiet Boot” 0
syscfg /bcs “admin@123” “Main” “Quiet Boot” 0 “POST Error Pause” 1
syscfg /bcs “admin@123” “system acoustic and performance configuration” “Set
throttling mode” 2 “Altitude” 900 “Set fan profile” 2
2. When BIOS administrator is not set.
syscfg /bcs "" “Quiet Boot” 0
syscfg /bcs "" “Main” “Quiet Boot” 0 “POST Error Pause” 1
syscfg /bcs "" “system acoustic and performance configuration” “Set throttling
mode” 2 “Altitude” 900 “Set fan profile” 2