Intel® Server Board S2600CO Family Technical Product Specification Intel order number G42278-004 Revision 1.
Revision History Intel® Server Board S2600CO Family TPS Revision History Date February, 2012 Revision Number 1.0 Modifications Initial release. June, 2012 1.1 Updated Thermal Management and Environmental Limits Specification. September, 2012 1.2 Updated PCIe slots definition and added NTB support section. August, 2013 1.3 Added E5-2600 v2 processor support September, 2013 1.4 Updated chapter 3.2.2.1 May, 2014 1.5 Updated chapter 3.2.2.2 July, 2014 1.
Intel® Server Board S2600CO Family TPS Table of Contents Table of Contents 1. Introduction ........................................................................................................................ 1 1.1 Chapter Outline ...................................................................................................... 1 1.2 Server Board Use Disclaimer ................................................................................. 2 2. Product Overview ...................................
Table of Contents Intel® Server Board S2600CO Family TPS 6.1 Baseboard Management Controller (BMC) Firmware Feature Support................. 52 6.1.1 IPMI 2.0 Features................................................................................................. 52 6.1.2 Non IPMI Features ............................................................................................... 53 6.1.3 New Manageability Features ................................................................................ 54 6.
Intel® Server Board S2600CO Family TPS Table of Contents 7.2.1 Availability ............................................................................................................ 81 7.2.2 Network Port Usage ............................................................................................. 81 8. On-board Connector/Header Overview ........................................................................... 82 8.1 Power Connectors ..............................................................
Table of Contents Intel® Server Board S2600CO Family TPS 9.2 Integrated BMC Force Update Procedure ............................................................ 97 9.3 ME Force Update Jumper .................................................................................... 97 9.4 BIOS Recovery Jumper ........................................................................................ 98 10. Light Guided Diagnostics ......................................................................................
Intel® Server Board S2600CO Family TPS List of Figures List of Figures Figure 1. Major Board Components ............................................................................................ 6 Figure 2. Intel® Light Guided Diagnostic LED Identification ......................................................... 7 Figure 3. Jumper Block Identification .......................................................................................... 8 Figure 4. Rear I/O Layout ..................................
List of Tables Intel® Server Board S2600CO Family TPS List of Tables Table 1. Intel® Server Board S2600CO Family Feature Set ........................................................ 3 Table 2. Mixed Processor Configurations Error Summary ......................................................... 18 Table 3. UDIMM Support Guidelines ......................................................................................... 22 Table 4. RDIMM Support Guidelines ..................................................
Intel® Server Board S2600CO Family TPS List of Tables Table 40. RMM4_Lite Connector Pin-out (RMM4_Lite) ............................................................. 90 Table 41. RMM4_NIC Connector Pin-out (RMM4_NIC) ............................................................ 90 Table 42. TPM Connector Pin-out (TPM) .................................................................................. 90 Table 43. PMBus* Connector Pin-out (SMB_PMBUS*) .........................................................
List of Tables Intel® Server Board S2600CO Family TPS Table 81. Integrated BMC Beep Codes ................................................................................... 151 x Revision 1.
Intel® Server Board S2600CO Family TPS List of Tables xi Revision 1.
Intel® Server Board S2600CO Family TPS 1. Introduction Introduction This Technical Product Specification (TPS) provides board-specific information detailing the features, functionality, and high-level architecture of the Intel® Server Board S2600CO. Design-level information related to specific server board components and subsystems can be obtained by ordering External Product Specifications (EPS) or External Design Specifications (EDS) related to this server generation.
Introduction 1.2 Intel® Server Board S2600CO Family TPS Server Board Use Disclaimer Intel Corporation server boards support add-in peripherals and contain a number of high-density VLSI (Very Large Scale Integration) and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components.
Intel® Server Board S2600CO Family TPS 2. Product Overview Product Overview The Intel® Server Board S2600CO is a monolithic printed circuit board (PCB) assembly with features designed to support the pedestal server markets. It has two board SKUs, namely S2600CO4 and S2600COE. These server boards are designed to support the Intel® Xeon® Processor E5-2600 or E5-2600 v2 product family. Previous generation Intel® Xeon® processors are not supported.
Product Overview Intel® Server Board S2600CO Family TPS Feature Description Add-in Card Slots Support up to six expansion slots ® Slot 1: PCIe Gen II x4 electrical with x8 physical connector, routed from Intel C600 Chipset, support half-length card Slot 2: PCIe Gen III x16 electrical with x16 physical connector, routed from CPU1, support full length card Slot 3: PCIe Gen III x16 electrical with x16 physical connector(blue slot), routed from CPU2, support full length, double width card Slot 4: PCIe
Intel® Server Board S2600CO Family TPS 2.1 Product Overview Server Board Connector and Component Layout The following illustrations provide a general overview of the server board, identifying key feature and component locations. Each connector and major component is identified by a number or letter, and the description is given below the figure.
Product Overview Callout Intel® Server Board S2600CO Family TPS Description Callout F double width card Battery AM G Slot 4, PCI Express* Gen3 AN H Slot 5, PCI Express* Gen3 (blue slot), supports double width card AO I Slot 6, PCI Express* Gen3 AP* J K L M N O P Q R S T U V W X Y Z DIMM E1/E2/F1/F2 Status LED ID LED Diagnostic LED NIC 3/4 USB 0/1/2/3, NIC 1,2 VGA CPU 2 Power connector System Fan 7 Serial Port A CPU 2 Fan Connector DIMM H1/H2/G1/G2 DIMM A1/A2/B1/B2 CPU 1 Power connector CPU
Intel® Server Board S2600CO Family TPS Product Overview ® Figure 2. Intel Light Guided Diagnostic LED Identification See Chapter 10 for additional details. Revision 1.
Product Overview Intel® Server Board S2600CO Family TPS Figure 3. Jumper Block Identification See Chapter 9 for additional details. 8 Revision 1.
Intel® Server Board S2600CO Family TPS Callout A B C D Product Overview Description Serial Port A Video NIC Port 1, USB Port 0 (top) and 1 (bottom) NIC Port 2, USB Port 2 (top) and 3 (bottom) Callout E F Description NIC Port 3 and 4 Diagnostics LED’s G ID LED H Status LED Figure 4. Rear I/O Layout Revision 1.
Product Overview 2.2 Intel® Server Board S2600CO Family TPS Server Board Dimensional Mechanical Drawings Figure 5. Mounting Hole Locations (1 of 2) 10 Revision 1.
Intel® Server Board S2600CO Family TPS Product Overview Figure 6. Mounting Hole Locations (2 of 2) Revision 1.
Product Overview Intel® Server Board S2600CO Family TPS Figure 7. Major Connector Pin-1 Locations 12 Revision 1.
Intel® Server Board S2600CO Family TPS Product Overview Figure 8. Primary Side Keep-out Revision 1.
Product Overview Intel® Server Board S2600CO Family TPS Figure 9. Secondary Side Keep-out 14 Revision 1.
Intel® Server Board S2600CO Family TPS 3. Functional Architecture Overview Functional Architecture Overview The architecture and design of the Intel® Server Board S2600CO is developed around the integrated features and functions of the Intel® Xeon® processor E5-2600 or E5-2600 v2 product family, the Intel® C602 chipset, the Intel® Ethernet Controller I350 Quad Port 1GbE chip, and the Server Engines* Pilot-III Server Management Controller.
Functional Architecture Overview 3.1 Intel® Server Board S2600CO Family TPS Processor Support The server board includes two Socket-R (LGA2011) processor sockets and can support one or two of the following processors: Intel® Xeon® processor E5-2600 or E5-2600 v2 product family, with a Thermal Design Power (TDP) of up to 135W.
Intel® Server Board S2600CO Family TPS Functional Architecture Overview testing of this configuration. For optimal system performance in dual-processor configurations, Intel recommends that identical processors be installed. When using a single processor configuration, the processor must be installed into the processor socket labeled “CPU_1”. When two processors are installed, the following population rules apply: Both processors must be of the same processor family.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS Minor: The message is displayed on the screen or on the Error Manager screen, and the POST Error Code is logged to the SEL. The system continues booting in a degraded state. The user may want to replace the erroneous unit. The POST Error Pause option setting in the BIOS setup does not have any effect on this error. Table 2.
Intel® Server Board S2600CO Family TPS Error Functional Architecture Overview Severity ® Processor Intel QuickPath Interconnect link frequencies not identical Fatal System Action The BIOS detects the QPI link frequencies and responds as follows: Adjusts all QPI interconnect link frequencies to highest common frequency. No error is generated – this is not an error condition. Continues to boot the system successfully.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS Processor Core Features: Up to 8 execution cores for Intel® Xeon® processor E5-2600 product family Up to 12 execution cores for Intel® Xeon® processor E5-2600 v2 product family Each core supports two threads (Intel® Hyper-Threading Technology), up to 16 threads per socket for Intel® Xeon® E5-2600 and 24 threads per socket for Intel® Xeon® E5-2600 v2 respectively 46-bit physical addressing and 48-bit virtual address
Intel® Server Board S2600CO Family TPS Functional Architecture Overview The physical connectivity of each interconnect link is made up of twenty differential signal pairs plus a differential forwarded clock. Each port supports a link pair consisting of two uni-directional links to complete the connection between two components. This supports traffic in both directions simultaneously.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS Minimum memory configuration: independent channel support with 1 DIMM populated Integrated dual SMBus* master controllers Command launch modes of 1n/2n RAS Support: o o o Rank Level Sparing and Device Tagging Demand and Patrol Scrubbing DRAM Single Device Data Correction (SDDC) for any single x4 or x8 DRAM device. Independent channel mode supports x4 SDDC.
Intel® Server Board S2600CO Family TPS Functional Architecture Overview Table 4. RDIMM Support Guidelines Ranks Per DIMM and Data Width Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel (DPC) Memory Capacity Per DIMM Intel® Server Board S2600CO (2 Slots per Channel) 1DPC 2DPC 1.35V 1.5V 1.35V 1.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS E5-2600 Processor QRx4 (DDP) 16GB 32GB 1066 1066, 1333 1066 1066, 1333 QRx8 (P) 8GB 16GB 1066 1066, 1333 1066 1066, 1333 E5-2600 v2 Processor 3.2.2.
Intel® Server Board S2600CO Family TPS Functional Architecture Overview On the Intel® Server Board S2600CO a total of 16 DIMM slots is provided (2 CPUs – 4 Channels/CPU, 2 DIMMs /Channel). The nomenclature for DIMM sockets is detailed in the following table: ® Table 6.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS Mixing of DDR3 operating frequencies is not validated within a socket or across sockets by Intel. If DIMMs with different frequencies are mixed, all DIMMs will run at the common lowest frequency. Quad rank RDIMMs are supported but not validated by Intel. A maximum of 8 logical ranks (ranks seen by the host) per channel is allowed.
Intel® Server Board S2600CO Family TPS Functional Architecture Overview same interface frequency but individual channels may run at different DIMM timings (RAS latency, CAS Latency, and so forth). 3.2.2.4.2 Lockstep Channel Mode In Lockstep Channel Mode the cache-line is split across channels. This is done to support Single Device Data Correction (SDDC) for DRAM devices with 8-bit wide data ports.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS Regardless of RAS mode, the requirements for populating within a channel given in the section 3.2.2.2 must be met at all times. Note that support of RAS modes that require matching DIMM population between channels (Mirrored and Lockstep) require that ECC DIMMs be populated. For Lockstep Channel Mode and Mirroring Mode, processor channels are paired together as a “Domain”.
Intel® Server Board S2600CO Family TPS Functional Architecture Overview Once a correctable memory error threshold is reached, the event is logged to the System Event Log (SEL) and the appropriate memory slot fault LED is lit to indicate on which DIMM the correctable error threshold crossing occurred. 3.2.2.5.2.2 Uncorrectable Memory ECC Error Handling All multi-bit “detectable but not correctable” memory errors are classified as Uncorrectable Memory ECC Errors. This is generally a fatal error.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS An SFO Event is logged to the BMC SEL. The failing rank is then disabled, and any further Correctable Errors on that now non-redundant channel will be disregarded. The correctable error that triggered the SFO may be logged to the BMC SEL, if it was the first one to occur in the system. That first correctable error event will be the only one logged for the system.
Intel® Server Board S2600CO Family TPS QPI CPU 1 QPI IOU1 IOU2 IOU0 P3 P1 P2 PCIe Gen3 x16 (32GB/s) DMI2 PCIe Gen2 x4 (4GB/s) P0 Intel® Xeon® E5-2600 PCIe Gen3 x4 (8GB/s) DMI2 Interface to the PCH: The platform requires an interface to the legacy Southbridge (PCH) which provides basic, legacy functions required for the server platform and operating systems.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS for the optional SAS Module. Features and functions of the Intel® C600 Series chipset will be described in its own dedicated section. 3.2.3.1 PCI Card Support The server board provides six PCI card slots identified by PCIe Slot 1 to PCIe Slot 6. The PCIe slot 1 is routed from Intel® C600 Series Chipset, The PCIe slot 2 and 5 are routed from CPU 1. The PCIe slot 3, 4, 6 are routed from CPU 2.
Intel® Server Board S2600CO Family TPS ® Functional Architecture Overview 8 Port SATA, PCIe Slot RAID Levels 0,1,10, 5, 50, 6, 60 Intel Integrated RAID Module RMT3PB080 RMT3PB080 For additional product information, please refer the following Intel documents: 1. Intel® Integrated RAID Module RMS25PB080, RMS25PB040, RMS25CB080, and RMS25CB040 Hardware/Installation User Guide 2. Intel Integrated RAID Module RMS25KB040, RMS25KB080, RMS25JB040, RMS25JB080 –Hardware/Installation User Guide 3.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS The server board has seven MAC addresses programmed at the factory.
Intel® Server Board S2600CO Family TPS Functional Architecture Overview Manageability Features 3.3.1 Non-Transparent Bridge PCI Express* Non-Transparent Bridge (NTB) acts as a gateway that enables high performance, low overhead communication between two intelligent subsystems, the local and the remote subsystems.
Functional Architecture Overview 3.3.3.1 Intel® Server Board S2600CO Family TPS eUSB SSD Support The server board provides support for a low profile eUSB SSD storage device. A 2mm 2x5-pin connector labeled “eUSB SSD” is used to plug this small flash storage device into. 3.3.4 On-board Serial Attached SCSI (SAS)/Serial ATA (SATA)/RAID Support and Options The Intel® C602 chipset provides storage support by two integrated controllers: Advanced Host Controller Interface (AHCI) and SCU.
Intel® Server Board S2600CO Family TPS Intel® RAID C600 Upgrade Key Options Functional Architecture Overview Key Color Description ® 4 Port SAS with Intel ESRT2 RAID 0,1, 10 and ® Intel RSTe RAID 0,1,10 RKSAS4 Green RKSAS4R5 Yellow 4 Port SAS with Intel ESRT2 RAID 0,1, 5, 10 ® and Intel RSTe RAID 0,1,10 RKSAS8 Orange 8 Port SAS with Intel ESRT2 RAID 0,1, 10 and ® Intel RSTe RAID 0,1,10 RKSAS8R5 Purple 8 Port SAS with Intel ESRT2 RAID 0,1, 5, 10 ® and Intel RSTe RAID 0,1,10 ® ® ® Additional
Functional Architecture Overview 3.3.4.
Intel® Server Board S2600CO Family TPS 3.4 Functional Architecture Overview Integrated Baseboard Management Controller Overview The server board utilizes the I/O controller, Graphics Controller, and Baseboard Management features of the Server Engines* Pilot-III Server Management Controller. The following is an overview of the features as implemented on the server board from each embedded controller. Intel® C600 Series Chipset USB[10] PCIe Gen1 x1 SMBUS PORTS USB 2.0 (480Mbs) USB[3] USB 1.
Functional Architecture Overview 3.4.
Intel® Server Board S2600CO Family TPS Functional Architecture Overview 2D Mode 1600x1200** 2D Video Mode Support 16 bpp 24 bpp Supported 8 bpp Supported 32 bpp ** Video resolutions at 1600x1200 and higher are only supported through the external video connector located on the rear I/O section of the server board. Utilizing the optional front panel video connector may result in lower video resolutions. The server board provides one video interfaces.
Functional Architecture Overview Intel® Server Board S2600CO Family TPS Six general-purpose timers Interrupt controller Multiple Serial Peripheral Interface (SPI) flash interfaces NAND/Memory interface Sixteen mailbox registers for communication between the BMC and host LPC ROM interface BMC watchdog timer capability SD/MMC card controller with DMA support LED support with programmable blink rate controls on GPIOs Port 80h snooping capability Secondary Service Pr
Intel® Server Board S2600CO Family TPS Technology Support 4. Technology Support 4.1 Intel® Trusted Execution Technology The Intel® Xeon® Processor E5 4600/2600/2400/1600 Product Families support Intel® Trusted Execution Technology (Intel® TXT), which is a robust security environment designed to help protect against software-based attacks. Intel® Trusted Execution Technology integrates new security features and capabilities into the processor, chipset and other platform components.
Technology Support Intel® Server Board S2600CO Family TPS For more information on the DMAR table and the DRHD entry format, refer to the Intel® Virtualization Technology for Directed I/O Architecture Specification. For more general information about VT-x, VT-d, and VT-c, a good reference is Enabling Intel® Virtualization Technology Features and Benefits White Paper. 4.
Intel® Server Board S2600CO Family TPS Technology Support power information utilized by the NM algorithms and also exports ACPI Source Language (ASL) code used by OS-Directed Power Management (OSPM) for negotiating processor P and T state changes for power limiting. PMBus*-compliant power supplies provide the capability to monitoring input power consumption, which is necessary to support NM. Following are the some of the applications of Intel® Intelligent Power Node Manager technology.
System Security Intel® Server Board S2600CO Family TPS 5. System Security 5.1 BIOS Password Protection The BIOS uses passwords to prevent unauthorized tampering with the server setup. Passwords can restrict entry to the BIOS Setup, restrict use of the Boot Popup menu, and suppress automatic USB device reordering. There is also an option to require a Power On password entry in order to boot the system.
Intel® Server Board S2600CO Family TPS System Security simply boot in the defined boot order, no password is required. However, the F6 Boot popup prompts for a password, and can only be used with the Administrator password. Also, when a User password is defined, it suppresses the USB Reordering that occurs, if enabled, when a new USB boot device is attached to the system. A User is restricted from booting in anything other than the Boot Order defined in the Setup by an Administrator.
System Security Intel® Server Board S2600CO Family TPS Verifies operator physical presence. Confirms and executes operating system TPM administrative command requests. Provides BIOS Setup options to change TPM security states and to clear TPM ownership. For additional details, refer to the TCG PC Client Specific Implementation Specification, the TCG PC Client Specific Physical Presence Interface Specification, and the Microsoft BitLocker* Requirement documents. 5.2.
Intel® Server Board S2600CO Family TPS System Security Press to enter setup When the Setup is entered, the Main screen displays. The BIOS Setup utility provides the Security screen to enable and set the user and administrative passwords and to lock out the front panel buttons so they cannot be used. The Intel® Server Board S5520URT provides TPM settings through the security screen. To access this screen from the Main screen, select the Security option.
System Security Intel® Server Board S2600CO Family TPS Table 14. Setup Utility – Security Configuration Screen Fields Setup Item TPM State* Options Enabled and Activated Enabled and Deactivated Disabled and Activated Disabled and Deactivated Help Text Comments Information only. Shows the current TPM device state. A disabled TPM device will not execute commands that use TPM functions and TPM security operations will not be available.
Intel® Server Board S2600CO Family TPS System Security virtual machine monitor, an OS or an application. In addition, Intel® Trusted Execution Technology requires the system to include a TPM v1.2, as defined by the Trusted Computing Group TPM PC Client Specifications, Revision 1.2. When available, Intel® Trusted Execution Technology can be enabled or disabled in the processor from a BIOS Setup option. Revision 1.
Platform Management Functional Overview 6.
Intel® Server Board S2600CO Family TPS Platform Management Functional Overview BMC self-test: The BMC performs initialization and run-time self-tests and makes results available to external entities. See also the Intelligent Platform Management Interface Specification Second Generation v2.0. 6.1.2 Non IPMI Features The BMC supports the following non-IPMI features. In-circuit BMC firmware update. Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality.
Platform Management Functional Overview 6.1.3 Intel® Server Board S2600CO Family TPS New Manageability Features ® Intel S2600CO Server Platforms offer a number of changes and additions to the manageability features that are supported on the previous generation of servers.
Intel® Server Board S2600CO Family TPS o 6.2 Platform Management Functional Overview BMC System Management Health Monitoring Advanced Configuration and Power Interface (ACPI) The server board has support for the following ACPI states: Table 15. ACPI Power States State S0 Supported Yes S1 Yes Description Working. The front panel power LED is on (not controlled by the BMC). The fans spin at the normal speed, as determined by sensor inputs. Front panel buttons work normally. Sleeping.
Platform Management Functional Overview Source Intel® Server Board S2600CO Family TPS Capabilities CPU Thermal External Signal Name or Internal Subsystem CPU Thermtrip WOL (Wake On LAN) LAN Turn power on 6.4 Turns power off BMC Watchdog The BMC FW is consistently called to perform system functions that are time-critical in that failure to provide these functions in a timely manner can result in system or component damage.
Intel® Server Board S2600CO Family TPS Platform Management Functional Overview FSB2 refers to the FRB algorithm that detects system failures during POST. The BIOS uses the BMC watchdog timer to back up its operation during POST. The BIOS configures the watchdog timer to indicate that it is using the timer for the FRB2 phase of the boot operation. After the BIOS has identified and saved the BSP information, it sets the FRB2 timer use bit and loads the watchdog timer with the new timeout internal.
Platform Management Functional Overview Intel® Server Board S2600CO Family TPS The BMC provides FRU device command access to its own FRU device and to the FRU devices throughout the server. The FRU device ID mapping is defined in the Platform Specific Information. The BMC controls the mapping of the FRU device ID to the physical device 6.8 System Event Log (SEL) The BMC implements the system event log as specified in the Intelligent Platform Management Interface Specification, Version 2.0.
Intel® Server Board S2600CO Family TPS Platform Management Functional Overview [Auto] – BIOS automatically detect and identify the appropriate thermal throttling mechanism based on DIMM type, airflow input, DIMM sensor availability.
Platform Management Functional Overview Front Panel Temperature Sensor1 Baseboard Temperature Sensor2 CPU Margin Sensors3,5,6 DIMM Thermal Margin Sensors3,5 Exit Air Temperature Sensor1, 4, 8 PCH Temperature Sensor4,6 On-board Ethernet Controller Temperature Sensors4, 6 Add-In Intel® SAS/IO Module Temperature Sensors4, 6 PSU Thermal Sensor4, 9 CPU VR Temperature Sensors4, 7 DIMM VR Temperature Sensors4, 7 Integrated BMC Temperature Sensor4, 7 Global Aggregate Ther
Intel® Server Board S2600CO Family TPS 6.9.2 Platform Management Functional Overview Memory Thermal Throttling The server board provides support for system thermal management through open loop throttling (OLTT) and closed loop throttling (CLTT) of system memory. Normal system operation uses closed-loop thermal throttling (CLTT) and DIMM temperature monitoring as major factors in overall thermal and acoustics management.
Platform Management Functional Overview Intel® Server Board S2600CO Family TPS Table 17. Standard ID Channel Assignments Channel ID Interface Support Sessions 0 Primary IPMB No 1 LAN 1 Yes 2 LAN 2 Yes 1 ® 3 LAN 3 (Provided by the Intel Dedicated Server Management NIC) Yes 4 Reserved Yes 5 USB No 6 Secondary IPMB No 7 SMM No 8 -0Dh Reserved - 2 0Eh Self 0Fh SMS/Receive Message Queue No Notes: 1. Optional hardware supported by the server system. 2.
Intel® Server Board S2600CO Family TPS Platform Management Functional Overview See the Intelligent Platform Management Interface Specification Second Generation v2.0 for details about the IPMI-over-LAN protocol. Run-time determination of LAN channel capabilities can be determined by both standard IPMI defined mechanisms. 6.10.3.1 RMCP/Alert Standard Forum (ASF Messaging) The BMC supports RMCP ping discovery in which the BMC responds with a pong message to an RMCP/ASF ping request.
Platform Management Functional Overview 6.10.3.2.
Intel® Server Board S2600CO Family TPS 6.10.3.3 Platform Management Functional Overview IPV6 Support In addition to IPv4, the server board has support for IPV6 for manageability channels. Configuration of IPv6 is provided by extensions to the IPMI Set and Get LAN Configuration Parameters commands as well as through a Web Console IPv6 configuration web page. The BMC supports IPv4 and IPv6 simultaneously so they are both configured separately and completely independently.
Platform Management Functional Overview 6.10.3.4 Intel® Server Board S2600CO Family TPS LAN Failover The BMC FW provides a LAN failover capability such that the failure of the system HW associated with one LAN link will result in traffic being rerouted to an alternate link.
Intel® Server Board S2600CO Family TPS 6.10.3.5.
Platform Management Functional Overview 6.10.3.5.
Intel® Server Board S2600CO Family TPS 6.10.5 Platform Management Functional Overview Internet Control Message Protocol (ICMP) The BMC supports the following ICMP message types targeting the BMC over integrated NICs: Echo request (ping): The BMC sends an Echo Reply. Destination unreachable: If message is associated with an active socket connection within the BMC, the BMC closes the socket. 6.10.6 Virtual Local Area Network (VLAN) The BMC supports VLAN as defined by IPMI 2.0 Specification.
Platform Management Functional Overview 6.10.7 Intel® Server Board S2600CO Family TPS Secure Shell (SSH) Secure Shell (SSH) connections are supported for SMASH-CLP sessions to the BMC. 6.10.8 Serial-over-LAN (SOL 2.0) The BMC supports IPMI 2.0 SOL. IPMI 2.0 introduced a standard serial-over-LAN feature. This is implemented as a standard payload type (01h) over RMCP+. Three commands are implemented for SOL 2.0 configuration. Get SOL 2.0 Configuration Parameters and Set SOL 2.
Intel® Server Board S2600CO Family TPS Platform Management Functional Overview Event Filter Number 10 Offset Mask Power down, power cycle, and reset Events Watchdog timer 11 OEM system boot event System restart (reboot) 12 Drive Failure, Predicated Failure Hot Swap Controller Additionally, the BMC supports the following PEF actions: Power off Power cycle Reset OEM action Alerts The “Diagnostic interrupt” action is not supported. 6.10.
Platform Management Functional Overview Intel® Server Board S2600CO Family TPS The BMC provides an embedded “lite” version of SM-CLP that is syntax-compatible but not considered fully compliant with the DMTF standards. The SM-CLP utilized by a remote user by connecting a remote system from one of the system NICs.
Intel® Server Board S2600CO Family TPS Platform Management Functional Overview A partial list of additional features supported by the web GUI includes: Presents all the Basic features to the users. Power on/off/reset the server and view current power state. Displays BIOS, BMC, ME and SDR version information. Display overall system health. Configuration of various IPMI over LAN parameters for both IPv4 and IPv6 Display system asset information for the product, board, and chassis.
Platform Management Functional Overview Intel® Server Board S2600CO Family TPS For any abnormal status LED state, Virtual Front Panel will get the reason behind the abnormal or status LED changes and displayed in VFP side. As Virtual Front Panel uses the chassis control command for power actions. It will not log the Front button press event since Logging the front panel press event for Virtual Front Panel press will mislead the administrator.
Intel® Server Board S2600CO Family TPS Platform Management Functional Overview “event-only”; meaning that they are not readable using an IPMI Get Sensor Reading command but rather are used just for event logging purposes). SEL – The current SEL contents are saved in both hexadecimal and text format. CPU/memory register data useful for diagnosing the cause of the following system errors: CATERR, ERR[2], SMI timeout, PERR, and SERR.
Platform Management Functional Overview 6.10.15.1 Intel® Server Board S2600CO Family TPS Output Data Format The diagnostic feature shall output a password-protected compressed HTML file containing specific BMC and system information. This file is not intended for end-customer usage, this file is for customer support and engineering only. 6.10.15.2 Output Data Availability The diagnostic data shall be available on-demand from the embedded web server, KCS, or IPMI over LAN commands. 6.10.15.
Intel® Server Board S2600CO Family TPS Platform Management Functional Overview be supported. No support for optional DCMI commands. Optional power management and SEL roll over feature is not supported. DCMI Asset tag will be independent of baseboard FRU asset Tag. 6.10.17 Lightweight Directory Authentication Protocol (LDAP) The Lightweight Directory Access Protocol (LDAP) is an application protocol supported by the BMC for the purpose of authentication and authorization.
Advanced Management Features Support (RMM4) 7. Intel® Server Board S2600CO Family TPS Advanced Management Features Support (RMM4) The integrated baseboard management controller has support for advanced management features which are enabled when an optional Intel® Remote Management Module 4 (RMM4) is installed. The Intel® RMM4 is available as two option kits: ® Table 21.
Intel® Server Board S2600CO Family TPS Advanced Management Features Support (RMM4) KVM redirection includes a “soft keyboard” function. The “soft keyboard” is used to simulate an entire keyboard that is connected to remote system. The “soft keyboard” functionality supports the following layouts: English, Dutch, French, German, Italian, Russian, and Spanish.
Advanced Management Features Support (RMM4) Intel® Server Board S2600CO Family TPS transitions from graphics to text or vice-versa. The responsiveness may be slightly delayed depending on the bandwidth and latency of the network. Enabling KVM and/or media encryption will degrade performance. Enabling video compression provides the fastest response while disabling compression provides better video quality. For the best possible KVM performance, a 2Mb/sec link or higher is recommended.
Intel® Server Board S2600CO Family TPS Advanced Management Features Support (RMM4) Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the server. It is possible to boot all supported operating systems from the remotely mounted device and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. See the Tested/supported Operating System List for more information.
On-board Connector/Header Overview 8. Intel® Server Board S2600CO Family TPS On-board Connector/Header Overview This section identifies the location and pin-out for on-board connectors and headers of the server board that provide an interface to system options/features, on-board platform management, or other user accessible options/features. 8.1 Power Connectors The server board includes several power connectors that are used to provide DC power to various devices. 8.1.
Intel® Server Board S2600CO Family TPS 8.1.3 On-board Connector/Header Overview PCIe Card Power Connectors The server board includes one 4-pin power connectors that provide support for add-in cards that require more power than is supported from the PCIe slots direct. The connector is labeled as OPT_12V_PWR. Table 25. PCIe Card Power Connector Pin-out (“OPT_12V_PWR”) 8.
On-board Connector/Header Overview Pin 29 8.2.1.1 Intel® Server Board S2600CO Family TPS Signal Name NIC#3 Link LED Pin 30 Signal Name NIC#4 Link LED Power/Sleep Button and LED Support Pressing the Power button will toggle the system power on and off. This button also functions as a sleep button if enabled by an ACPI compliant operating system. Pressing this button will send a signal to the integrated BMC, which will power on or power off the system.
Intel® Server Board S2600CO Family TPS On-board Connector/Header Overview Table 28. NMI Signal Generation and Event Logging NMI Causal Event Signal Generation Chassis Control command (pulse diagnostic interrupt) X – Front panel diagnostic interrupt button pressed X X Watchdog Timer pre-timeout expiration with NMI/diagnostic interrupt action X X 8.2.1.
On-board Connector/Header Overview Color State Intel® Server Board S2600CO Family TPS Criticality Description supply configuration was present. Unable to use all of the installed memory (one or more DIMMs failed/disabled but functional memory remains available) Correctable Errors over a threshold and migrating to a spare DIMM (memory sparing). This indicates that the user no longer has spared DIMMs indicating a redundancy lost condition. Corresponding DIMM LED lit.
Intel® Server Board S2600CO Family TPS Color State On-board Connector/Header Overview Criticality Description Both uBoot BMC FW images are bad. (Chassis ID shows blue/solid-on for this condition) 240VA fault Fatal Error in processor initialization: Processor family not identical Processor model not identical Processor core/thread counts not identical Processor cache size not identical Unable to synchronize processor frequency Unable to synchronize QPI link frequency 8.2.
On-board Connector/Header Overview 8.3.1 Intel® Server Board S2600CO Family TPS SATA Only Connectors: 6 Gbps The server board includes two white single port SATA only connectors capable of transfer rates of up to 6Gb/s. On the server board these connectors are labeled as SATA_0 and SATA_1. The following table provides the pin-out for both connectors. Table 32.
Intel® Server Board S2600CO Family TPS On-board Connector/Header Overview ® Table 35. Intel RAID C600 Upgrade Key Connector Pin-out (STOR UPG KEY) Pin 1 2 3 4 8.3.5 Signal Name GND FM_PBG_DYN_SKU_KEY GND FM_SSB_SAS_SATA_RAID_KEY HSBP_I2C Header 2 2 Table 36. HSBP_I C Header Pin-out (HSBP_I C) Pin 1 2 3 8.3.6 Signal Name SMB_HSBP_3V3STBY_DATA GND SMB_HSBP_3V3STBY_CLK HDD LED Header The server board includes a 2-pin hard drive activity LED header used with some SATA/SAS controller add-in cards.
On-board Connector/Header Overview Intel® Server Board S2600CO Family TPS Table 39. Internal eUSB Connector Pin-out (eUSB_SSD) 8.4 Pin Signal Name 1 3 5 7 +5V USB_N USB_P GND Pin Signal Name 2 4 6 8 10 NC NC NC NC LED# Management and Security Connectors 8.4.1 RMM4_Lite Connector ® A 7-pin Intel RMM4 Lite Connector is included on the server board to support the optional Intel® Remote Management Module 4. There is no support for third-party management cards on this server board.
Intel® Server Board S2600CO Family TPS Pin 3 5 7 9 11 13 8.4.4 On-board Connector/Header Overview Signal Name LPC_LAD<0> IRQ_SERIAL P3V3 RST_IBMC_NIC_N_R2 LPC_LAD<3> GND Pin 4 6 8 10 12 14 Signal Name GND LPC_FRAME_N GND CLK_33M_TPM GND LPC_LAD<2> PMBus* Connector Table 43. PMBus* Connector Pin-out (SMB_PMBUS*) Pin 1 2 3 4 5 8.4.
On-board Connector/Header Overview 8.5.1 Intel® Server Board S2600CO Family TPS System FAN Connectors The server board provides support for seven system cooling fans. Each connector is monitored and controlled by on-board platform management. On the server board, each system fan connector is labeled SYS_FAN_#, where # = 1 thru 7.
Intel® Server Board S2600CO Family TPS On-board Connector/Header Overview Pin 5 7 9 8.6.2 Signal Name GND SPA_RTS SPA_RI Pin 6 8 Signal Name SPA_DSR SPA_CTS Serial Port B Connector Serial-B is an internal 10-pin DH-10 connector labeled as SERIAL_B and has the following pinout: Table 51. Serial-B Connector Pin-out (SERIAL_B) Pin 1 3 5 7 9 8.6.
On-board Connector/Header Overview 8.7 8.7.1 Intel® Server Board S2600CO Family TPS Other Connectors and Headers FAN BOARD_I2C Connector Note: Only Intel® Server Board S2600CO4 includes this FAN BOARD_I2C connector. The server board includes a 4-pin I2C header that is intend to be used for third party fan control circuits using a Maxim 72408 controller. On the server board, this header is labeled FAN BOARD_I2C. The header has the following pin-out. 2 2 Table 53.
Intel® Server Board S2600CO Family TPS 9. Reset and Recovery Jumpers Reset and Recovery Jumpers The server board includes several jumper blocks which are used to as part of a process to restore a board function back to a normal functional state. The following diagram and sections identify the location of each jumper block and provides a description of their use. The following symbol identifies Pin 1 on each jumper block on the silkscreen: ▼ Figure 22.
Reset and Recovery Jumpers Jumper Name Default (that is, CMOS Clear) Pins 2-3 Intel® Server Board S2600CO Family TPS System Results If pins 2-3 are connected when AC power unplugged, the CMOS settings clear in 5 seconds. Pins 2-3 should not be connected for normal system operation.
Intel® Server Board S2600CO Family TPS Reset and Recovery Jumpers 5. Power up the server and wait 10 seconds or until POST completes. 6. Power down the server. 7. Open the chassis and move the jumper back to the default position (covering pins 1 and 2). 8. Close the server chassis. 9. Power up the server. The password is now cleared and can be reset by going into the BIOS setup. 9.
Reset and Recovery Jumpers Intel® Server Board S2600CO Family TPS firmware update process fails due to ME not being in the proper update state, the server board provides an Integrated BMC Force Update jumper, which forces the ME into the proper update state. The following procedure should be completed in the event the standard ME firmware update process fails. 1. Power down and remove the AC power cord. 2. Open the server chassis. For instructions, see your server chassis documentation. 3.
Intel® Server Board S2600CO Family TPS Light Guided Diagnostics 10. Light Guided Diagnostics The server board includes several on-board LED indicators to aid troubleshooting various board level faults. This section provides a description of the location and function of each LED on the server boards. 10.1 5 Volt Stand-by LED Several server management features of these server boards require a 5V stand-by voltage supplied from the power supply.
Light Guided Diagnostics Intel® Server Board S2600CO Family TPS Figure 24. Fan Fault LED’s Location 100 Revision 1.
Intel® Server Board S2600CO Family TPS Light Guided Diagnostics 10.3 DIMM Fault LEDs The server board provide memory fault LED for each DIMM socket. These LEDs are located as shown in the following figure. The DIMM fault LED illuminates when the corresponding DIMM slot has memory installed and a memory error occurs. Figure 25. DIMM Fault LED’s Location 10.4 System ID LED, System Status LED and POST Code Diagnostic LEDs The server boards provide LEDs for system ID, system status and POST code.
Light Guided Diagnostics Intel® Server Board S2600CO Family TPS A Callout Description System Status LED B System ID LED LSB 1 2 3 4 5 6 MSB POST Code Diagnostic LEDs Figure 26. Location of System Status, System ID and POST Code Diagnostic LEDs 10.4.1 System ID LED You can illuminate the blue System ID LED using either of the following two mechanisms: By pressing the System ID Button on the system front control panel, the ID LED displays a solid blue color until the button is pressed again.
Intel® Server Board S2600CO Family TPS 10.4.2 Light Guided Diagnostics System Status LED The bi-color (green/amber) System Status LED operates as follows: Table 56. System Status LED Color State Criticality Description Green Solid on System OK System booted and ready. Degraded System degraded Non-critical temperature threshold asserted Non-critical voltage threshold asserted o Non-critical fan threshold asserted o Fan redundancy lost, sufficient system cooling maintained.
Light Guided Diagnostics Intel® Server Board S2600CO Family TPS Table 57. POST Code Diagnostic LEDs A. Diagnostic LED #7 (MSB LED) E. Diagnostic LED #3 B. Diagnostic LED #6 F. Diagnostic LED #2 C. Diagnostic LED #5 G. Diagnostic LED #1 D. Diagnostic LED #4 H. Diagnostic LED #0 (LSB LED) 104 Revision 1.
Intel® Server Board S2600CO Family TPS Environmental Limits Specification 11. Environmental Limits Specification The following table defines the Intel® Server Board S2600CO operating and non-operating environmental limits. Operation of the Intel® Server Board S2600CO at conditions beyond those shown in the following table may cause permanent damage to the system. Exposure to absolute maximum rating conditions for extended periods may affect system reliability. Table 58.
Environmental Limits Specification Intel® Server Board S2600CO Family TPS fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel® developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions.
Intel® Server Board S2600CO Family TPS Power Supply Specification Guidelines 12. Power Supply Specification Guidelines This section provides power supply specification guidelines recommended for providing the specified server platform with stable operating power requirements. Note: The power supply data provided in this section is for reference purposes only. It reflects Intel®’s own DC power out requirements for a 550W power supply as used in an Intel® designed 4U server platform.
Power Supply Specification Guidelines 3.3V 5.0V Intel® Server Board S2600CO Family TPS 12V1 12V2 12V3 -12V 5.0Vstby Total Power 12V Power 3.3V/5V Power Load4 2.5 2 13.1 13.1 18 0 0.3 550 530 18 Load5 0.5 0.3 15 15 6.5 0.5 3 462 438 3 Load6 16 4 1 1 3.5 0 0.3 140 66 73 Load7 16 13 1 1 9 0.5 3 271 132 118 12.1.3 Standby Output The 5VSB output is present when an AC input greater than the power supply turn on voltage is applied. 12.1.3.
Intel® Server Board S2600CO Family TPS Power Supply Specification Guidelines Table 64. Capacitive Loading Conditions 12.1.3.4 Output +3.3V 250 Min 5000 Max F Units +5V 400 5000 F +12V 500 8000 F -12V 1 350 F +5VSB 20 350 F Grounding The output ground of the pins of the power supply provides the output power return path. The output connector ground pins are connected to the safety ground (power supply enclosure).
Power Supply Specification Guidelines Intel® Server Board S2600CO Family TPS The test set-up is as shown below: VOUT AC HOT POWER SUPPLY V RETURN AC NEUTRAL LOAD MUST BE ISOLATED FROM THE GROUND OF THE POWER SUPPLY LOAD 10uF .1uF AC GROUND GENERAL NOTES: 1. LOAD THE OUTPUT WITH ITS MINIMUM LOAD CURRENT. 2. CONNECT THE PROBES AS SHOWN. 3. REPEAT THE MEASUREMENTS WITH THE MAXIMUM LOAD ON THE OUTPUT.
Intel® Server Board S2600CO Family TPS Power Supply Specification Guidelines Vout 10% Vout V1 V2 V3 V4 Tvout_off Tvout_rise Tvout_on Figure 28. Output Voltage Timing Table 67. Turn On/Off Timing Item Tsb_on_delay Description Delay from AC being applied to 5VSB being within regulation. Tac_on_delay Delay from AC being applied to all output voltages being within regulation. Tvout_holdup Time all output voltages stay within regulation after loss of AC. Tested at 75% of maximum load.
Power Supply Specification Guidelines Intel® Server Board S2600CO Family TPS AC Input Tvout_holdup Vout Tpwok_low TAC_on_delay Tsb_on_delay Tpwok_on PWOK 5VSB Tpwok_off Tsb_on_delay Tpwok_on Tpwok_off Tpson_pwok Tpwok_holdup T5VSB_holdup Tsb_vout Tpson_on_delay PSON AC turn on/off cycle PSON turn on/off cycle Figure 29. Turn On/Off Timing (Power Supply Signals) 112 Revision 1.
Intel® Server Board S2600CO Family TPS Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips When adding or removing components or peripherals from the server board, AC power must be removed. With AC power plugged into the server board, 5-V standby is still present even though the server board is powered off. This server board supports The Intel® Xeon® Processor E5-2600 or E5-2600 v2 product family with a Thermal Design Power (TDP) of up to and including 135 W.
Appendix B: Compatible Intel® Server Chassis Intel® Server Board S2600CO Family TPS Appendix B: Compatible Intel® Server Chassis Intel® Server Chassis P4000M Family is 4U pedestal, 25'' length server chassis that is designed to support Intel® Server Board S2600CO. It also provides a rackable feature. A. B. C. D. E. F. G. H. I. J. K. L. M. N. O.
Intel® Server Board S2600CO Family TPS Appendix B: Compatible Intel® Server Chassis A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q. R. 750-W Hot Swap Power Supply (Two) AC Input Power Connector (Two) I/O Ports Alternate RMM4 Knockout PCI Add-in Board Slot Covers Serial Port Knockout A Kensington* Cable Lock Mounting Hole Padlock Loop Alternate RMM4 Knockout Hot-swap System Fan 5 Front Control Panel Hot-swap System Fan 4 5.25’’ Peripheral Bays Hot-swap System Fan 3 Hot-swap System Fan 2 8x3.
Appendix B: Compatible Intel® Server Chassis Intel® Server Board S2600CO Family TPS The following figure shows the server chassis/system product code naming conventions: Figure 32. Chassis/System Product Code Naming Conventions The Intel® Server Chassis P4000M family comes with the following configurations: 1. P4308XXMFEN – one 550-W non-redundant fixed PSU, two non-redundant fixed 120x38mm system fans and up to eight 3.5" fixed hard drives. 2.
Intel® Server Board S2600CO Family TPS Appendix B: Compatible Intel® Server Chassis 13. P4216XXMHEN – one 550-W non-redundant fixed PSU, two non-redundant fixed 120x38mm system fans and up to sixteen 2.5" hot-swap hard drives. 14. P4308XXMHGR – two 750-W redundant hot-swap PSU, two non-redundant fixed 120x38mm system fans and up to eight 3.5" hot-swap hard drives. 15. P4308XXMHGN – one 750-W hot-swap PSU, two non-redundant fixed 120x38mm system fans and up to eight 3.5" hot-swap hard drives. 16.
Appendix B: Compatible Intel® Server Chassis Intel® Server Board S2600CO Family TPS Configuration P4308XXMFEN P4308XXMHEN P4308XXMFGN P4308XXMHGC P4308XXMHJC activity LED, System status LED, two USB ports, Optional front serial port/VGA port Appearance Color: Cosmetic black (GE 701 or equivalent), service Intel blue, hot swap Intel green. ® Support for Intel standard front panel or LCD Dimensions Pedestal 17.24 in (438 mm) x 6.
Intel® Server Board S2600CO Family TPS Appendix B: Compatible Intel® Server Chassis Configuration P4308XXMFEN P4308XXMHEN sixteen 2.5” hot-swap hard drives. P4308XXMFGN swap hard drive cage. Supports up to eight 3.5” hot-swap hard drives. P4308XXMHGC bay. Supports up to eight 3.5” fixed hard P4308XXMHJC eight 3.5” hot-swap hard drives. Expansion Slots Support up to six (6) full height, full length PCI form factor cards mechanically.
Appendix C: Integrated BMC Sensor Tables Intel® Server Board S2600CO Family TPS Appendix C: Integrated BMC Sensor Tables This appendix provides BMC core sensor information common to all Intel® server boards within this generation of product. Specific server boards and/or server platforms may only implement a sub-set of sensors and/or may include additional sensors. The actual sensor name associated with a sensor number may vary between server boards or systems.
Intel® Server Board S2600CO Family TPS Appendix C: Integrated BMC Sensor Tables Rearm Sensors The rearm is a request for the event status for a sensor to be rechecked and updated upon a transition between good and bad states. Rearming the sensors can be done manually or automatically. This column indicates the type supported by the sensor.
Appendix C: Integrated BMC Sensor Tables Intel® Server Board S2600CO Family TPS Table 69. BMC Core Sensors Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers 00 - Power down Power Unit Status 01h (Pwr Unit Status) All Power Unit 09h Sensor Specific 6Fh 02 - 240 VA power down 04 - A/C lost Contrib.
Intel® Server Board S2600CO Family TPS Full Sensor Name (Sensor name in SDR) Sensor # Appendix C: Integrated BMC Sensor Tables Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Appendix C: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Sensor # (Fan Redundancy) SSB Thermal Trip (SSB Therm Trip) IO Module Presence (IO Mod Presence) SAS Module Presence (SAS Mod Presence) BMC Firmware Health (BMC FW Health) System Airflow (System Airflow) Intel® Server Board S2600CO Family TPS Platform Applicability Sensor Type specific 04h 0Dh All 0Eh Platformspecific 0Fh 10h 11h Platformspecific All All Event/ Reading Type 0Bh Temperature 01h Digital Discrete
Intel® Server Board S2600CO Family TPS Full Sensor Name (Sensor name in SDR) Baseboard Temperature 1 (Platform Specific) Front Panel Temperature (Front Panel Temp) SSB Temperature (SSB Temp) Baseboard Temperature 2 (Platform Specific) Baseboard Temperature 3 (Platform Specific) Baseboard Temperature 4 (Platform Specific) IO Module Temperature (I/O Mod Temp) PCI Riser 1 Temperature (PCI Riser 1 Temp) IO Riser Temperature (IO Riser Temp) Appendix C: Integrated BMC Sensor Tables Sensor # Platform Applicabil
Appendix C: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Intel® Server Board S2600CO Family TPS Sensor # Platform Applicability Sensor Type Event/ Reading Type 2Bh Chassisspecific Temperature Threshold 01h 01h Platformspecific Temperature Threshold 01h 01h Platformspecific Temperature Threshold 01h 01h Chassis and Platform Specific Temperature Threshold 01h 01h Temperature Threshold 01h 01h Hot-swap Backplane 3 Temperature (HSBP 3 Temp) PCI Riser 2 Temper
Intel® Server Board S2600CO Family TPS Full Sensor Name (Sensor name in SDR) Sensor # Appendix C: Integrated BMC Sensor Tables Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers 06 – Configuration error Power Supply 1 AC Power Input 54h (PS1 Power In) Power Supply 2 AC Power Input 55h (PS2 Power In) Power Supply 1 +12V % of Maximum Current Output 58h (PS1 Curr Out %) Power Supply 2 +12V % of Maximum Current Output 59h (PS2 Curr Out %) Power Supply 1 Temperature (PS1 T
Appendix C: Integrated BMC Sensor Tables Intel® Server Board S2600CO Family TPS Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Processor 1 Thermal Margin (P1 Therm Margin) 74h All Processor 2 Thermal Margin (P2 Therm Margin) 75h All 78h All Processor 1 Thermal Control % (P1 Therm Ctrl %) Processor 2 Thermal Control % 79h All (P2 Therm Ctrl %) Processor 1 ERR2 Timeout (P1 ERR2) Processor 2 ERR2 Timeout (P2 ERR2) Catastrophic Error (CATERR) Processor0 MSID Mismatch (P0 M
Intel® Server Board S2600CO Family TPS Appendix C: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Processor 2 VRD Temperature 91h All (P2 VRD Hot) Processor 1 Memory VRD Hot 0-1 (P1 Mem01 VRD Hot) Processor 1 Memory VRD Hot 2-3 (P1 Mem23 VRD Hot) Processor 2 Memory VRD Hot 0-1 (P2 Mem01 VRD Hot) 94h 95h 96h All All All Sensor Type Temperature 01h Temperature 01h Temperature 01h Temperature 01h Processor 2 Memory VRD Hot 2-3 (P2 Mem23 VRD H
Appendix C: Integrated BMC Sensor Tables Intel® Server Board S2600CO Family TPS Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Processor 1 DIMM Thermal Trip (P1 Mem Thrm Trip) C0h All Temperature 01h C1h All Temperature 01h Digital Discrete 03h C8h Platform Specific Temperature Threshold 01h 01h C9h Platform Specific Temperature Threshold 01h 01h CAh Platform Specific Temperature Threshold 01h 01h CBh Platform Specific Temperature Threshold 01h 01h
Intel® Server Board S2600CO Family TPS Full Sensor Name (Sensor name in SDR) Baseboard +3.3V (BB +3.3V) Baseboard +5V Stand-by (BB +5.0V STBY) Baseboard +3.3V Auxiliary (BB +3.3V AUX) Baseboard +1.05V Processor 1 Vccp Sensor # D2h D3h D4h D6h Appendix C: Integrated BMC Sensor Tables Platform Applicability All All All All (BB +1.05Vccp P1) Baseboard +1.05V Processor 1 Vccp D7h All (BB +1.05Vccp P2) Baseboard +1.5V P1 Memory AB VDDQ D8h All (BB +1.5 P1MEM AB) Baseboard +1.
Appendix C: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Baseboard CMOS Battery (BB +3.3V Vbat) Baseboard +1.
Intel® Server Board S2600CO Family TPS Appendix D: Intel® Server Board S2600CO Family Specific Sensors Appendix D: Intel® Server Board S2600CO Family Specific Sensors Product ID Bytes 11:12 (product ID) of Get Device ID command response: 5Dh 00h ACPI S3 Sleep State Support Not supported.
Appendix D: Intel® Server Board S2600CO Family Specific Sensors Intel® Server Board S2600CO Family TPS Hot-plug fan support Supported on: Intel® Server Chassis P4208 (UPM with redundant fan 4U) Intel® Server Chassis P4216 (UPM with redundant fan 4U) Intel® Server Chassis P4308 (UPM with redundant fan 4U) Fan redundancy support Supported on: Intel® Server Chassis P4208 (UPM with redundant fan 4U) Intel® Server Chassis P4216 (UPM with redundant fan 4U) Intel® Server Chassis P4308 (UPM wit
Intel® Server Board S2600CO Family TPS Chassis Appendix D: Intel® Server Board S2600CO Family Specific Sensors Major Components Cooled (Temperature sensor number) HSBP 1 Temp (29h) HSBP 2 Temp (2Ah) Exit Air Temp (2Eh) P1 Therm Margin (74h) P2 Therm Margin (75h) DIMM Thrm Mrgn 1 (B0h) DIMM Thrm Mrgn 2 (B1h) DIMM Thrm Mrgn 3(B2h) DIMM Thrm Mrgn 4 (B3h) 6 P1 MEM01 VRD Hot (94h) Processor 1 Fan (36h) 7 P1 MEM23 VRD Hot (95h) BB P2 VR Temp (24h) Processor 2 Fan (37h) 0
Appendix D: Intel® Server Board S2600CO Family Specific Sensors Chassis Major Components Cooled (Temperature sensor number) P1 Therm Margin (74h) P2 Therm Margin (75h) DIMM Thrm Mrgn 1 (B0h) DIMM Thrm Mrgn 2 B1h) DIMM Thrm Mrgn 3 (B2h) DIMM Thrm Mrgn 4 (B3h) BB P2 VR Temp (24h) HSBP 1 Temp (29h) HSBP 2 Temp (2Ah) Exit Air Temp (2Eh) PS1 Temperature (5Ch) PS2 Temperature (5Dh) P2 Therm Margin (75h) DIMM Thrm Mrgn 1 (B0h) DIMM Thrm Mrgn 4 (B3h) Fan Domain 4 Intel® Server B
Intel® Server Board S2600CO Family TPS PS Module Number 1200W HS Power Supply PMBus* Supported Appendix D: Intel® Server Board S2600CO Family Specific Sensors Product Name (in product area of the FRU) DPS-1200TB A PSU Redundant Supported Cold Redundant Supported Fans in each PS 2 PS fan Redundant Fans only for Intel® Server Chassis Intel® Server Chassis P4208 (UPM with redundant fan 4U) Intel® Server Chassis P4216 (UPM with redundant fan 4U) Intel® Server Chassis P4308 (UPM with redundant
Appendix E: Management Engine Generated SEL Event Messages Intel® Server Board S2600CO Family TPS Appendix E: Management Engine Generated SEL Event Messages This appendix lists the OEM System Event Log message format of events generated by the Management Engine (ME). This includes the definition of event data bytes 10-16 of the Management Engine generated SEL records. For System Event Log format information, see the Intelligent Platform Management Interface Specification, Version 2.0. Table 73.
Intel® Server Board S2600CO Family TPS Appendix E: Management Engine Generated SEL Event Messages Table 74. Node Manager Health Event Node Manager Health Event Request Byte 1 - EvMRev =04h (IPMI2.
Appendix F: POST Code Diagnostic LED Decoder Intel® Server Board S2600CO Family TPS Appendix F: POST Code Diagnostic LED Decoder As an aid to assist in troubleshooting a system hang that occurs during a system’s Power-On Self Test (POST) process, the server board includes a bank of eight POST Code Diagnostic LEDs on the back edge of the server board.
Intel® Server Board S2600CO Family TPS Appendix F: POST Code Diagnostic LED Decoder The following table provides a list of all POST progress codes: Table 76.
Appendix F: POST Code Diagnostic LED Decoder Intel® Server Board S2600CO Family TPS Diagnostic LED Decoder 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble Checkpoint MSB 8h 4h #7 #6 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 LED # 99h 9Ah 9Bh 9Ch 9Dh A1h A2h A3h A4h A5h A6h A7h A8h A9h ABh ACh ADh AEh AFh B0h B1h B2h B3h B4h B5h B6h B7h 00h S3 Resume E0h 1 E1h 1 E2h 1 E3h 1 BIOS Recovery F0h 1 F1h 1 F2h 1 F3h 1 F4h 1 Description 2
Intel® Server Board S2600CO Family TPS Appendix F: POST Code Diagnostic LED Decoder Table 77.
Appendix F: POST Code Diagnostic LED Decoder Intel® Server Board S2600CO Family TPS Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB 8h LED #7 Description (with MRC Internal Minor Code) LSB 4h #6 2h #5 1h #4 8h #3 4h #2 2h #1 1h #0 03h = No memory installed. All channels are disabled.
Intel® Server Board S2600CO Family TPS Appendix G: Post Code Errors Appendix G: POST Code Errors Most error conditions encountered during POST are reported using POST Error Codes. These codes represent specific failures, warnings, or informational messages. POST Error Codes may be displayed in the Error Manager display screen, and are always logged to the System Event Log (SEL). Logged events are available to System Management applications, including Remote and Out of Band (OOB) management.
Appendix G: POST Code Errors Intel® Server Board S2600CO Family TPS Error Code Error Message Response 0192 Processor cache size mismatch detected Fatal 0194 Processor family mismatch detected Fatal 0195 Processor Intel QPI link frequencies unable to synchronize Fatal 0196 Processor model mismatch detected Fatal 0197 Processor frequencies unable to synchronize Fatal 5220 BIOS Settings reset to default settings Major 5221 Passwords cleared by jumper Major 5224 Password clear jumper
Intel® Server Board S2600CO Family TPS Appendix G: Post Code Errors Error Code Error Message Response 852A DIMM_D2 failed test/initialization Major 852B DIMM_D3 failed test/initialization Major 852C DIMM_E1 failed test/initialization Major 852D DIMM_E2 failed test/initialization Major 852E DIMM_E3 failed test/initialization Major 852F DIMM_F1 failed test/initialization Major 8530 DIMM_F2 failed test/initialization Major 8531 DIMM_F3 failed test/initialization Major 8532 DIMM_G1
Appendix G: POST Code Errors Intel® Server Board S2600CO Family TPS Error Code Error Message Response 8557 DIMM_H3 disabled Major 8558 DIMM_I1 disabled Major 8559 DIMM_I2 disabled Major 855A DIMM_I3 disabled Major 855B DIMM_J1 disabled Major 855C DIMM_J2 disabled Major 855D DIMM_J3 disabled Major 855E DIMM_K1 disabled Major 855F (Go to 85D0) DIMM_K2 disabled Major 8560 DIMM_A1 encountered a Serial Presence Detection (SPD) failure Major 8561 DIMM_A2 encountered a Serial Pr
Intel® Server Board S2600CO Family TPS Appendix G: Post Code Errors Error Code Error Message Response 85C2 DIMM_L2 failed test/initialization Major 85C3 DIMM_L3 failed test/initialization Major 85C4 DIMM_M1 failed test/initialization Major 85C5 DIMM_M2 failed test/initialization Major 85C6 DIMM_M3 failed test/initialization Major 85C7 DIMM_N1 failed test/initialization Major 85C8 DIMM_N2 failed test/initialization Major 85C9 DIMM_N3 failed test/initialization Major 85CA DIMM_O1
Appendix G: POST Code Errors Intel® Server Board S2600CO Family TPS Error Code Error Message Response 8604 POST Reclaim of non-critical NVRAM variables Minor 8605 BIOS Settings are corrupted Major 8606 NVRAM variable space was corrupted and has been reinitialized Major 92A3 Serial port component was not detected Major 92A9 Serial port component encountered a resource conflict error Major A000 TPM device not detected. Minor A001 TPM device missing or not responding.
Intel® Server Board S2600CO Family TPS Appendix G: Post Code Errors Table 81. Integrated BMC Beep Codes Code Reason for Beep Associated Sensors 1-5-2-1 CPU socket population error CPU1 socket is empty, or sockets are populated incorrectly CPU1 must be populated before CPU2.
Glossary Intel® Server Board S2600CO Family TPS Glossary This appendix contains important terms used in the preceding chapters. For ease of use, numeric entries are listed first (for example, 82460GX) with alpha entries following (for example, AGP 4x). Acronyms are then entered in their respective place, with non-acronyms following.
Intel® Server Board S2600CO Family TPS Glossary Term INTR Interrupt Definition IP Internet Protocol IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface IR Infrared ITP In-Target Probe KB 1024 bytes KCS Keyboard Controller Style LAN Local Area Network LCD Liquid Crystal Display LED Light Emitting Diode LPC Low Pin Count LUN Logical Unit Number MAC Media Access Control MB 1024KB mBMC National Semiconductor* PC87431x mini BMC MCH Memory Co
Glossary Term Intel® Server Board S2600CO Family TPS SMI Definition Server Management Interrupt (SMI is the highest priority nonmaskable interrupt) SMM Server Management Mode SMS Server Management Software SNMP Simple Network Management Protocol TBD To Be Determined TIM Thermal Interface Material UART Universal Asynchronous Receiver/Transmitter UDP User Datagram Protocol UHCI Universal Host Controller Interface UTC Universal time coordinare VID Voltage Identification VRD Voltage Reg
Intel® Server Board S2600CO Family TPS Reference Documents Reference Documents 1. Advanced Configuration and Power Interface Specification, Revision 3.0, http://www.acpi.info/ 2. Intelligent Platform Management Bus Communications Protocol Specification, Version 1.0. 1998. Intel Corporation, Hewlett-Packard* Company, NEC* Corporation, Dell* Computer Corporation 3. Intelligent Platform Management Interface Specification, Version 2.0. 2004.