Document
Monthly Specification Update Enterprise Platforms and Services Marketing
12
24.
Integrated BMC Web Console – Sensor Readings Page – Memory
Throttling sensor status will stay “Critical” once triggered
Problem When Memory Throttling is triggered, the Memory “P1 MTT and/or P2 MTT”
sensor status will stay at “Critical” status in the Integrated BMC Web Console
even after throttling has stopped.
Implication You may observe Memory “P1 MTT and/or P2 MTT” status as “Critical” even
when there is no throttling. No functional impact to the system.
Status This issue may be fixed in a future ME release.
Workaround Need a AC cycle or reset ME through IPMI to reset the MTT sensor status.
25.
WOL (Wake on LAN) may not function under Red Hat* Linux 6.2 64bit OS
Problem With Intel
®
LAN driver version 17.1, WOL (Wake on LAN) may not function
under Red Hat* Linux 6.2 64bit OS.
Implication You may not be able to wake system through onboard NIC port.
Status This issue may be fixed in a future LAN driver release.
Workaround None.
26.
Intel
®
server system R1000EP fan might take longer time to slow down
the spin speed.
Problem Intel
®
server system R1000EP fan might take longer time to slow down the spin
speed.
Implication You may observe the fan might take longer time than 20seconds to slow down
the spin speed.
Status This issue may be fixed in a future BIOS or BMC release.
Workaround None.
27.
Intel
®
server system R1000EP COO label includes inaccurate information
Problem Intel
®
server system R1000EP COO label includes redundant information that
needs to be removed.
Implication There is “x2” follwing powerating “6/3A”, which is showed in the left snapshot.
The correct label should be as the right snapshot indicates.