Document

Monthly Specification Update Enterprise Platforms and Services Marketing
10
18.
Intel
®
RAID C600 Upgrade Key replacement Issue
Problem With Manageability Engine (ME) Firmware 02.01.05.069, the Intel
®
Server
Board S2400EP and Intel
®
Server System R1000EP may detect the incorrect
Storage Control Unit (SCU) Redundant Array of Inexpensive/Independent
Disks (RAID) information after installing or replacing the RAID upgrade key.
The board or system may still show the previous RAID information even if you
replace the key with a new one.
Implication With the ME firmware 02.01.05.069, the system may not detect the new RAID
activation key during the first time AC power on.
Status The issue is fixed with ME firmware 02.01.05.091.
Workaround Do a second AC power cycle to the system after the RAID upgrade key has
been installed or replaced to ensure the correct type of key is identified.
19.
Intel
®
LAN driver installation failure on Microsoft Windows* 7
Problem The Intel
®
LAN driver version 16.8 and below may not be installed sucessfully
on Microsoft Windows* 7 with the .bat installation scripts in the driver package.
Implication The LAN driver can not be installed by the .bat installation scripts in the driver
package.
Status The issue is fixed in Intel
®
LAN driver version 17.1
Workaround Two workarounds are availalbe:
1. The LAN driver can be manually installed.
2. User can lower the User Account Controlto Never Notify, then the driver
can be installed with the .bat installation scripts.
20.
Hard drives connected through SAS expander can’t be detected in
legacy mode
Problem If hard drives are connected through expander to SCU ports and configured
under RSTe mode, the hard drives can’t be detected by system in legacy mode
(default BIOS setting).
Implication Users can’t use the hard drives connected through expander as boot device to
install OS. But users can install OS to other hard drives which are not
connected through expander and load RSTe driver to make the hard drives
connected through expander visible to OS. Or users can change Boot
Options > EFI Optimized Boot to Enabled in BIOS Setup so that hard drives
connected through expander can be detected by the system.
Status This issue may be fixed in a future BIOS release.