Technical Product Specification

Appendix C: Management Engine Generated SEL Event Messages Intel
®
Server Board S2400EP TPS
Intel order number G50763-002 Revision 2.0
136
Table 64. Server Platform Services Firmware Health Event
Server Platform Services
Firmware Health Event
Request
Byte 1 - EvMRev
=04h (IPMI2.0 format)
Byte 2 Sensor Type
=DCh (OEM)
Byte 3 Sensor Number
=23 Server Platform Services Firmware Health
Byte 4 Event Dir | Event Type
[7] Event Dir
=0 Assertion Event
[6-0] Event Type
=75h (OEM)
Byte 5 Event Data 1
[7,6]=10b OEM code in byte 2
[5,4]=10b OEM code in byte 3
[3..0] Health Event Type
=00h Firmware Status
Byte 6 Event Data 2
=0 - Forced GPIO recovery. Recovery Image loaded due to
MGPIO<n> (default recovery pin is MGPIO1) pin asserted.
Repair action: Deassert MGPIO1 and reset the ME
=1 - Image execution failed. Recovery Image loaded because
operational image is corrupted. This may be either caused by Flash
device corruption or failed upgrade procedure.
Repair action: Either the Flash device must be replaced (if error is
persistent) or the upgrade procedure must be started again.
=2 - Flash erase error. Error during Flash erases procedure probably
due to Flash part corruption.
Repair action: The Flash device must be replaced.
=3 Flash corrupted. Error while checking Flash consistency
probably due to Flash part corruption.
Repair action: The Flash device must be replaced (if error is
persistent).
=4 Internal error. Error during firmware execution.
Repair action: FW Watchdog Timeout
Operational image shall be upgraded to other version or hardware
board repair is needed (if error is persistent).
=5..255 Reserved
Byte 7 Event Data 3
=<Extended error code. Should be used when reporting an error to
the support>