Technical Product Specification

Intel
®
Server Board S2400EP TPS Appendix B: BMC Sensor Tables
Revision 2.0 Intel order number G50763-002 129
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
Hard Disk Drive 16 - 24
Status
(HDD 16 - 24 Status)
60h
68h
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
6Fh
00 - Drive
Presence
OK
As and
De
Trig Offset
A
X
01- Drive Fault
Degraded
07 -
Rebuild/Remap
in progress
Degraded
Processor 1 Status
(P1 Status)
70h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig Offset
M
X
07 - Presence
OK
Processor 2 Status
(P2 Status)
71h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig Offset
M
X
07 - Presence
OK
Processor 1 Thermal
Margin
(P1 Therm Margin)
74h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 2 Thermal
Margin
(P2 Therm Margin)
75h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 1 Thermal
Control %
(P1 Therm Ctrl %)
78h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
Trig Offset
A
Processor 2 Thermal
Control %
(P2 Therm Ctrl %)
79h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
Trig Offset
A
Processor 1 ERR2
Timeout
(P1 ERR2)
7Ch
All
Processor
07h
Digital
Discrete
03h
01 State
Asserted
fatal
As and
De
Trig Offset
A