Technical Product Specification

Intel
®
Server Board S2400EP TPS Appendix B: BMC Sensor Tables
Revision 2.0 Intel order number G50763-002 123
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
04 Non-
redundant:
sufficient
resources.
Transition from
insufficient state.
Degraded
05 - Non-
redundant:
insufficient
resources
Fatal
06 Redundant:
degraded from
fully redundant
state.
Degraded
07 Redundant:
Transition from
non-redundant
state.
Degraded
IPMI Watchdog
(IPMI Watchdog)
03h
All
Watchdog 2
23h
Sensor
Specific
6Fh
00 - Timer
expired, status
only
OK
As
Trig Offset
A
X
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer
interrupt
Physical Security
(Physical Scrty)
04h
Chassis
Intrusion is
chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
00 - Chassis
intrusion
OK
As and
De
Trig Offset
A
X
04 - LAN leash
lost