Technical Product Specification
Appendix B: BMC Sensor Tables Intel
®
Server Board S2400EP TPS
Intel order number G50763-002 Revision 2.0
122
Note: All sensors listed below may not be present on all platforms. Please check platform EPS section for platform applicability and
platform chassis section for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate
hardware to support redundancy (for instance, fan or power supply)
Table 63. Integrated BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
Power Unit Status
(Pwr Unit Status)
01h
All
Power Unit
09h
Sensor
Specific
6Fh
00 - Power down
OK
As and
De
–
Trig Offset
A
X
02 - 240 VA
power down
Fatal
04 - A/C lost
OK
05 - Soft power
control failure
Fatal
06 - Power unit
failure
Power Unit
RedundancyNote1 (Pwr
Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully
Redundant
OK
As and
De
–
Trig Offset
A
X
01 - Redundancy
lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-
redundant:
sufficient
resources.
Transition from
full redundant
state.
Degraded