Rearm Sensors
The rearm is a request for the event status of a sensor to be rechecked and updated
upon a transition between good and bad states. You can rearm the sensors manually or
automatically. This column indicates the type supported by the sensor. The following
abbreviations are used in the comment column to describe a sensor:
o A: Auto-rearm
o M: Manual rearm
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which is 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls
the behavior of the Control Panel Status LED.
Standby
Some sensors operate on standby power. You can access these sensors and/or
generate events when the main (system) power is off but AC power is present.