Technical Product Specification

Intel
®
Server System R1000EP Product Family TPS Product Family Overview
Revision 2.0 Intel Order Number G67599-003 7
2.2 System Level Environmental Limits
The following table defines the system level operating and non-operating environmental limits.
Table 2. System Environmental Limits Summary
Parameter
Limits
Temperature
Operating
ASHRAE Class A2 Continuous Operation. 10ºC to 35ºC (50ºF to 95ºF) with the
maximum rate of change not to exceed 10°C per hour
ASHRAE Class A3 Includes operation up to 40ºC for up to 900 hours per year.
ASHRAE Class A4 Includes operation up to 45ºC for up to 90 hours per year.
Shipping
-40ºC to 70ºC (-40ºF to 158ºF)
Altitude
Operating
Support operation up to 3050m with ASHRAE class deratings.
Humidity
Shipping
50% to 90%, non-condensing with a maximum wet bulb of 28° C (at temperatures
from 25°C to 35°C)
Shock
Operating
Half sine, 2g, 11 mSec
Unpackaged
Trapezoidal, 25g, velocity change is based on packaged weight
Packaged
Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged
5 Hz to 500 Hz 2.20 g RMS random
Packaged
5 Hz to 500 Hz 1.09 g RMS random
AC-DC
Voltage
90 Hz to 132 V and 180 V to 264 V
Frequency
47 Hz to 63 Hz
Source
Interrupt
No loss of data for power line drop-out of 12 mSec
Surge Non-
operating and
operating
Unidirectional
Line to earth
Only
AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Air Discharged
12.0 kV
Contact
Discharge
8.0 kV
Acoustics
Sound
Power
Measured
Power in
Watts
<300 W ≥300 W ≥600 W ≥1000 W