Status This issue may be fixed in future shippment.
Workaround None.
28.
The MAC address of Dual Port Intel
®
X540 10GbE I/O
Module(AXX10GBTWLIOM and AXX10GBTWLHW) in BIOS displays as all
zero
Problem With BIOS R01.06.0001, the MAC address of Dual Port Intel® X540 10GbE I/O
Module(AXX10GBTWLIOM and AXX10GBTWLHW) in BIOS displays as all
zero.
Implication Users are not able to check the MAC address of Dual Port Intel® X540 10GbE
I/O Module(AXX10GBTWLIOM and AXX10GBTWLHW) in BIOS.
Status This issue may be fixed in a future BIOS release.
Workaround None.
29.
BMC will generate flood event log and send PEF continuously
Problem 1. Use IPMI tool to set a PEF (6 commands)
ipmitool H xxx.xxx.xxx.xxx U xxx P xxxxxx raw 0x04 0x12 0x01 0x01
ipmitool H xxx.xxx.xxx.xxx U xxx P xxxxxx raw 0x04 0x12 0x02 0x01
ipmitool H xxx.xxx.xxx.xxx U xxx P xxxxxx raw 0x04 0x12 0x9 0x14 0xa8
0x1f 0x0
ipmitool H xxx.xxx.xxx.xxx U xxx P xxxxxx raw 0x04 0x12 0x6 0x14 0x80
0x1 0xa 0x10 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
ipmitool H xxx.xxx.xxx.xxx U xxx P xxxxxx raw 0x0c 0x01 0x1 0x12 0xf
0x80 0x5 0x7
ipmitool H xxx.xxx.xxx.xxx U xxx P xxxxxx raw 0x0c 0x01 0x1 0x13 0xf 0x0
0x0 0xa 0x24 0x71 0x7b 0x0 0x0 0x0 0x0 0x0 0x0
2. Go to BMC web console and go to configurations=>alert, check all alert and
must set destination IP to remote concole =>Save
3. Try to generate an event (unplug power), you can see there are a lot of event in
event log and make event log full.
4. Even when restore the PSU, the SEL is continuing to grow w/o PSU
redundancy regain.