Specification update
Enterprise Platforms and Services Marketing Monthly Specification Update
13
Status This issue may be fixed in future shippment.
Workaround None.
28.
The MAC address of Dual Port Intel
®
X540 10GbE I/O
Module(AXX10GBTWLIOM and AXX10GBTWLHW) in BIOS displays as all
zero
Problem With BIOS R01.06.0001, the MAC address of Dual Port Intel® X540 10GbE I/O
Module(AXX10GBTWLIOM and AXX10GBTWLHW) in BIOS displays as all
zero.
Implication Users are not able to check the MAC address of Dual Port Intel® X540 10GbE
I/O Module(AXX10GBTWLIOM and AXX10GBTWLHW) in BIOS.
Status This issue may be fixed in a future BIOS release.
Workaround None.
29.
BMC will generate flood event log and send PEF continuously
Problem 1. Use IPMI tool to set a PEF (6 commands)
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x04 0x12 0x01 0x01
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x04 0x12 0x02 0x01
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x04 0x12 0x9 0x14 0xa8
0x1f 0x0
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x04 0x12 0x6 0x14 0x80
0x1 0xa 0x10 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x0c 0x01 0x1 0x12 0xf
0x80 0x5 0x7
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x0c 0x01 0x1 0x13 0xf 0x0
0x0 0xa 0x24 0x71 0x7b 0x0 0x0 0x0 0x0 0x0 0x0
2. Go to BMC web console and go to configurations=>alert, check all alert and
must set destination IP to remote concole =>Save
3. Try to generate an event (unplug power), you can see there are a lot of event in
event log and make event log full.
4. Even when restore the PSU, the SEL is continuing to grow w/o PSU
redundancy regain.