Document

Enterprise Platforms and Services Marketing Monthly Specification Update
5
4.
HDD status LEDs do not function under specific configuration
Problem If drives are connected through expander to SCU ports and configured under
RSTe mode, the HDD status LEDs may not function properly.
Implication HDD status LED may not show the HDD locate, HDD fault or RAID rebuild
message.
Status This issue is fixed in RSTe driver 3.2.01134 and later version.
Workaround None.
5.
RSTe GUI installation may fail if there are no devices attached to any
onboard AHCI ports
Problem When Microsoft Windows 2008* R2 is installed on SCU ports, the installation of
RSTe drivers and the Graphic User Interface (GUI) in Microsoft Windows 2008*
R2 will fail, if the AHCI controller is enabled while no device is attached to the
AHCI SATA ports.
Implication User may not be able to install RSTe GUI under mentioned configuration when
the AHCI controller is enabled and no devices are attached to the AHCI SATA
ports.
Status This issue may be fixed in a future RAID driver.
Workaround The workaround is to either plug a SATA device into one of the AHCI SATA
ports, or disable the onboard AHCI controller in BIOS.
6.
BMC continuously sends RAID volume rebuild event in RSTe mode of the
SCU controller
Problem When RSTe RAID is in degraded mode and a drive is inserted to start the
RAID rebuild, System Event Log (SEL) records drive plug and rebuild events
and then continuously sends a rebuild event message.
Implication User may see the SEL flooded with RAID volume rebuild event entries.
Status This issue was fixed in BMC 1.04.
Workaround None.