Technical Product Specification

Product Architecture Overview Intel
®
Server Board S2400EP TPS
Intel order number G50763-002 Revision 2.0
38
BMC LAN channel 1 MAC address = NIC1 MAC address + 2
BMC LAN channel 2 MAC address = NIC1 MAC address + 3
BMC LAN channel 3 (RMM4) MAC address = NIC1 MAC address + 4
The printed MAC address on the server board and/or server system is assigned to NIC1 on the
server board.
3.3.5 Embedded Serial ATA (SATA)/Serial Attached SCSI (SAS)/RAID Support
Integrated on the server board is an Intel
®
C600-A chipset that provides embedded storage
support via two integrated controllers: AHCI and SCU.
The standard server board (with no additional storage options installed) will support up to six
SATA ports:
Two 6 Gb/sec SATA port routed from the AHCI controller to two white 7-pin SATA port
labeled “SATA-1” on the server board.
Four 3 Gb/sec SATA ports routed from the SCU controller to the multi-port mini-SAS
connector labeled “SCU_0”.
Note: The mini-SAS connector labeled “SCU_1 (4-7)” is NOT functional by default and is only
enabled with the addition of an Intel
®
RAID C600 Upgrade Key option supporting eight
SAS/SATA ports.
The server board is capable of supporting additional chipset embedded SAS, SATA, and RAID
options when configured with one of several available Intel
®
RAID C600 Upgrade Keys.
Upgrade keys install onto a 4-pin connector on the server board labeled “STOR_UPG_KEY”.
Figure 21.Intel
®
RAID C600 Upgrade Key Connector
The following table identifies available upgrade key options and their supported features.