Technical Product Specification

Intel
®
Server Board S2400EP TPS Appendix B: BMC Sensor Tables
Revision 2.0 Intel order number G50763-002 131
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
Processor 2 Memory
VRD Hot 2-3
(P2 Mem23 VRD Hot)
97h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
Trig Offset
A
Power Supply 1 Fan
Tachometer 1
(PS1 Fan Tach 1)
A0h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State
Asserted
Non-fatal
As and
De
-
Trig Offset
M
-
Power Supply 1 Fan
Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State
Asserted
Non-fatal
As and
De
-
Trig Offset
M
-
Power Supply 2 Fan
Tachometer 1
(PS2 Fan Tach 1)
A4h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State
Asserted
Non-fatal
As and
De
-
Trig Offset
M
-
Power Supply 2 Fan
Tachometer 2
(PS2 Fan Tach 2)
A5h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State
Asserted
Non-fatal
As and
De
-
Trig Offset
M
-
Processor 1 DIMM
Aggregate Thermal
Margin
(P1 DIMM Thrm Mrgn)
B0h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
Processor 2 DIMM
Aggregate Thermal
Margin
(P2 DIMM Thrm Mrgn)
B1h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
Processor 1 DIMM
Thermal Trip
(P1 Mem Thrm Trip)
C0h
All
Temperature
01h
Digital
Discrete
03h
01 State
Asserted
Fatal
As and
De
Trig Offset
M
X
Processor 2 DIMM
Thermal Trip
(P2 Mem Thrm Trip)
C1h
All
Temperature
01h
Digital
Discrete
03h
01 State
Asserted
Fatal
As and
De
Trig Offset
M
X
Global Aggregate
Temperature Margin 1
(Agg Therm Mrgn 1)
C8h
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A