Technical Product Specification

Appendix B: BMC Sensor Tables Intel
®
Server Board S2400EP TPS
Intel order number G50763-002 Revision 2.0
128
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
06
Configuration
error
OK
Power Supply 2 Status
(PS2 Status)
51h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig Offset
A
X
01 - Failure
Degraded
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK
Power Supply 1
AC Power Input
(PS1 Power In)
54h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 2
AC Power Input
(PS2 Power In)
55h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 1 +12V %
of Maximum Current
Output
(PS1 Curr Out %)
58h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 2 +12V %
of Maximum Current
Output
(PS2 Curr Out %)
59h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 1
Temperature
(PS1 Temperature)
5Ch
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 2
Temperature
(PS2 Temperature)
5Dh
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X