Technical Product Specification
Intel
®
Server Board S2400EP TPS Appendix B: BMC Sensor Tables
Revision 2.0 Intel order number G50763-002 125
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
03 - Non-
redundant:
Sufficient
resources.
Transition from
redundant
Degraded
04 - Non-
redundant:
Sufficient
resources.
Transition from
insufficient.
Degraded
05 - Non-
redundant:
insufficient
resources.
Non-Fatal
06 – Non-
Redundant:
degraded from
fully redundant.
Degraded
07 - Redundant
degraded from
non-redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh
All
Temperature
01h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and
De
–
Trig Offset
M
X
IO Module Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Boar
d
15h
Digital
Discrete
08h
01 –
Inserted/Present
OK
As and
De
–
Trig Offset
M
X
SAS Module Presence
(SAS Mod Presence)
0Fh
Platform-
specific
Module/Boar
d
15h
Digital
Discrete
08h
01 –
Inserted/Present
OK
As and
De
–
Trig Offset
M
X
BMC Firmware Health
(BMC FW Health)
10h
All
Mgmt Health
28h
Sensor
Specific
6Fh
04 – Sensor
Failure
Degraded
As
-
Trig Offset
A
X