Technical Product Specification

Appendix B: BMC Sensor Tables Intel
®
Server Board S2400EP TPS
Intel order number G50763-002 Revision 2.0
124
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
FP Interrupt
(FP NMI Diag Int)
05h
Chassis -
specific
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front panel
NMI/diagnostic
interrupt
OK
As
Trig Offset
A
SMI Timeout
(SMI Timeout)
06h
All
SMI Timeout
F3h
Digital
Discrete
03h
01 State
asserted
Fatal
As and
De
Trig Offset
A
System Event Log
(System Event Log)
07h
All
Event
Logging
Disabled
10h
Sensor
Specific
6Fh
02 - Log area
reset/cleared
OK
As
Trig Offset
A
X
System Event
(System Event)
08h
All
System
Event
12h
Sensor
Specific
6Fh
02 -
Undetermined
system H/W
failure
04 PEF action
Fatal
OK
As and
De
As
-
Trig Offset
A
X
Button Sensor
(Button)
09h
All
Button/Switc
h
14h
Sensor
Specific
6Fh
00 Power
Button
02 Reset
Button
OK
AS
_
Trig Offset
A
X
BMC Watchdog
0Ah
All
Mgmt
System
Health
28h
Digital
Discrete
03h
01 State
Asserted
Degraded
As
Trig Offset
A
-
Voltage Regulator
Watchdog
(VR Watchdog)
0Bh
All
Voltage
02h
Digital
Discrete
03h
01 State
Asserted
Fatal
As and
De
Trig Offset
M
X
Fan RedundancyNote1
(Fan Redundancy)
0Ch
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully
redundant
OK
As and
De
Trig Offset
A
01 - Redundancy
lost
Degraded
02 - Redundancy
degraded
Degraded