Technical Product Specification
Intel
®
Server Board S2400EP TPS Intel
®
Light Guided Diagnostics
Revision 2.0 Intel order number G50763-002
109
Color
State
Criticality
Description
BMC booting Linux*. (Indicated by Chassis ID solid ON). System in
degraded state (no manageability). Control has been passed from
BMC uBoot to BMC Linux* itself. It will be in this state for ~10-~20
seconds.
BMC Watchdog has reset the BMC.
Power Unit sensor offset for configuration error is asserted.
HDD HSC is off-line or degraded.
Amber
~1 Hz blink
Non-critical -
System is
operating in a
degraded state
with an impending
failure warning,
although still
functioning
Non-fatal alarm – system is likely to fail:
Critical threshold crossed – Voltage, temperature (including HSBP
temp), input power to power supply, output current for main power
rail from power supply and PROCHOT (Therm Ctrl) sensors.
VRD Hot asserted.
Minimum number of fans to cool the system not present or failed
Hard drive fault
Power Unit Redundancy sensor – Insufficient resources offset
(indicates not enough power supplies present)
In non-sparing and non-mirroring mode if the threshold of
correctable errors is crossed within the window
Correctable memory error threshold has been reached for a failing
DDR3 DIMM when the system is operating in a non-redundant
mode
Amber
Solid on
Critical, non-
recoverable –
System is halted
Fatal alarm – system has failed or shutdown:
CPU CATERR signal asserted
MSID mismatch detected (CATERR also asserts for this case).
CPU 1 is missing
CPU Thermal Trip
No power good – power fault
DIMM failure when there is only 1 DIMM present and hence no
good memory present.
Runtime memory uncorrectable error in non-redundant mode.
DIMM Thermal Trip or equivalent
SSB Thermal Trip or equivalent
CPU ERR2 signal asserted
BMC\Video memory test failed. (Chassis ID shows blue/solid-on for
this condition)
Both uBoot BMC FW images are bad. (Chassis ID shows
blue/solid-on for this condition)
240VA fault
Fatal Error in processor initialization:
Processor family not identical
Processor model not identical
Processor core/thread counts not identical
Processor cache size not identical
Unable to synchronize processor frequency
Unable to synchronize QPI link frequency
10.3 BMC Boot/Reset Status LED Indicators
During the BMC boot or BMC reset process, the System Status LED and System ID LED are
used to indicate BMC boot process transitions and states. A BMC boot will occur when AC
power is first applied to the system. A BMC reset will occur after: