Specification Update
Monthly Specification Update
2
Summary Tables of Changes
The following tables provide an overview of known errata and known document changes that
apply to the specified Intel Server Products. The tables use the following notations:
Doc:
Intel intends to update the appropriate documentation in a future revision.
Fix:
Intel intends to fix this erratum in the future.
Fixed:
This erratum has been previously fixed.
No Fix:
There are no plans to fix this erratum.
Shaded:
This erratum is either new or has been modified from the previous specification
update.
Table 1. Errata Summary
No. Plans Description of Errata
1. Fix Linux* Operating Systems are not supported on RSTe mode.
2. Fixed UEFI Microsoft Windows Server 2008* R2 SP1 installation on SCU ports may fail under RSTe RAID
mode.
3. No Fix UEFI Operating System installation is not supported on ESRT2 mode.
4. Fixed HDD status LEDs do not function under specific configuration.
5. Fixed RSTe GUI installation may fail if there are no devices attached to any onboard AHCI ports.
6. Fixed System may halt under specific BIOS configurations.
7. Fixed Microsoft Windows 2003* x86 installation failure under Pass-through mode of SCU controller.
8. Fixed System may halt under unsupported configuration in ESRT2 mode.
9. Fixed Integrated BMC Web Console – Power Statistics page – Minimum wattage reads as zero.
10. Fixed Integrated BMC Web Console – Power Control page – Perform Action button not functional.
11. Fixed IPMI Get Chassis Status command returns incorrect Chassis Identify State.
12. Fixed The BIOS and ME Firmware can't be updated successfully using Intel
®
One Boot Flash Update
Utility (OFU) under SuSE* Linux Enterprise Server 11 (64-bit) with SP2.
13. Fixed BMC continuously sends HDD assert/de-assert event during HDD RAID rebuild under ESRT2 mode
of the SCU controller.
14. Fixed High CPU utilization may occur when installing or running Microsoft Windows Server 2008* R2 or
Microsoft Windows* 7 with default NIC driver for Intel
®
Gigabit ET Dual Port Server Adapter
E1G42ET and Intel
®
Gigabit ET Quad Port Server Adapter E1G44ET.
15. Fixed Intel
®
LAN driver installation failure on Microsoft Windows* 7.
16. Fixed Hard drives connected through SAS expander can’t be detected in legacy mode.
17. Fixed On-board VGA cannot be set to the highest resolution (1920x1080 and higher).
18. Fixed Integrated BMC Web Console – Sensor Readings Page – Memory Throttling sensor status will stay
“Critical” once triggered.
19. Fixed WOL (Wake on LAN) may not function under Red Hat* Linux 6.2 64-bit OS.
20. Fixed System only reports the first occurance of power redundancy loss
21. Fixed The MAC address of Dual Port Intel® X540 10GbE I/O Module(AXX10GBTWLIOM and
AXX10GBTWLHW) in BIOS displays as all zero.
22. Fix BMC will generate event log until it full and send PEF continuely