Specification Update
Monthly Specification Update
11
22. BMC will generate flood event log and send PEF continuously
Problem 1. Use IPMI tool to set a PEF (6 commands)
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x04 0x12 0x01 0x01
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x04 0x12 0x02 0x01
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x04 0x12 0x9 0x14 0xa8
0x1f 0x0
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x04 0x12 0x6 0x14 0x80
0x1 0xa 0x10 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x0c 0x01 0x1 0x12 0xf
0x80 0x5 0x7
ipmitool –H xxx.xxx.xxx.xxx –U xxx –P xxxxxx raw 0x0c 0x01 0x1 0x13 0xf 0x0
0x0 0xa 0x24 0x71 0x7b 0x0 0x0 0x0 0x0 0x0 0x0
2. Go to BMC web console and go to configurations=>alert, check all alert and
must set destination IP to remote concole =>Save
3. Try to generate an event (unplug power), you can see there are a lot of event in
event log and make event log full.
4. Even when restore the PSU, the SEL is continuing to grow w/o PSU
redundancy regain.
Implication The flood even log will fulfill the SEL in several minutes
Status The issue may be fix in future BMC release
Workaround Restore the system and uncheck all alerts in BMC web console.
23. Intel® FDR InfiniBand* ConnectX* -3 I/O Module may not comply with FCC
and Industry Canada regulations
Problem Intel® FDR InfiniBand* ConnectX* -3 I/O Module AXX1FDRIBIOM and
AXX2FDRIBIOM may not comply with Part 15 of the Federal Communications
Commission (FCC) and Industry Canada regulations when used with copper
InfiniBand* cables.
Implication Except for not complying with FCC and Industry Canada regulations when used
with copper InfiniBand* cables, no other functionality impact. And except for the
United States of America and Canada where the regulations apply, no other
countries are impacted.
Status This issue was fixed by Mellanox* InfiniBand* ConnectX* -3 firmware 2.11.1308
and later release. Please refer to the following website for downloading:
http://www.mellanox.com/page/firmware_table_Intel
Workaround This product must be used with optical cables in the United States of America
and Canada to comply with FCC and Industry Canada regulations.