Service Guide

Appendix A: Technical Reference
48 Intel
®®
Server System R1000SP Service Guide
Appendix A: Technical Reference
Power Supply Input Voltages
460W power supply module
100 - 127 V at 50/60 Hz 5.8 A
200 - 240 V at 50/60 Hz 2.9 A
750W power supply module
100 - 127 V at 50/60 Hz 8.2 A
200 - 240 V at 50/60 Hz 4.4 A
Power Supply Output Voltages
The following table lists the total wattage available from the power subsystem for each voltage. For
information about calculating the power usage for your configuration, please use the Power Budget
Tool.
Table 4. Power Supply Output Capability
Voltage
Maximum Current
12V
62.0A
12VSB
2.1A
System Environmental Specifications
The following table defines the system level operating and non-operating environmental limits.
Table 5. System Environmental Limits Summary
Parameter
Limits
Temperature
Operating
ASHRAE Class A2 Continuous Operation. 10ºC to 35ºC (50ºF to 95º F)
with the maximum rate of change not to exceed 10°C per hour
ASHRAE Class A3 Includes operation up to 40ºC for up to 900 hrs per
year.
ASHRAE Class A4 Includes operation up to 45ºC for up to 90 hrs per
year.
Shipping
-40ºC to 70ºC (-40ºF to 158ºF)
Altitude
Operating
Support operation up to 3050m with ASHRAE class deratings.
Humidity
Shipping
50% to 90%, non-condensing with a maximum wet bulb of 28°C (at
temperatures from 25°C to 35°C)
Shock
Operating
Half sine, 2g, 11 mSec