Service Guide

Server System Features
8 Intel
®
Server System R1000SP Service Guide
7. DIMM Fault LEDs on the server board help identify failed and failing DIMM slots. The DIMM
fault LEDs turn on (amber) if there is a DIMM fault.
System Recovery Jumpers
Jumper Name
Jumper Purpose
BMC Force Update
If pins 2-3 are selected, the Integrated BMC Force Update Mode is
enabled. These pins should be selected on 1-2 for normal system
operation.
BIOS Recover
If pins 2-3 are selected, the system can only boot from EFI-bootable
recovery media with the recovery BIOS image. The main system
BIOS will not boot. These pins should be selected on 1-2 for normal
system operation.
Password Clear
If pins 2-3 are selected, administrator and user passwords are cleared
within five to ten seconds after the system is powered on. These pins
should be selected on 1-2 for normal system operation.
ME Force Update
If pins 2-3 are selected, the ME Force Update Mode is enabled.
These pins should be selected on 1-2 for normal system operation.
BIOS Default
If pins 2-3 are selected, the BIOS settings are cleared on the next
reset. These pins should be selected on 1-2 for normal system
operation.
Figure 10. Configuration Jumpers