Technical Product Specification
Appendix B: Integrated BMC Sensor Tables Intel® Server Board S1400SP TPS
Intel order number G64248-003 Revision 2.1
124
Full Sensor Name
(Sensor name in
SDR)
Sensor # Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Standby
Processor 1
VRD
Temperature
(P1 VRD Hot)
90h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
M –
Processor 2
VRD
Temperature
(P2 VRD Hot)
91h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
M –
Processor 3
VRD
Temperature
(P3 VRD Hot)
92h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
–
Trig
Offset
M –
Processor 4
VRD
Temperature
(P4 VRD Hot)
93h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
–
Trig
Offset
M –
Processor 1
Memory VRD
Hot 0-1
(P1 Mem01 VRD
Hot)
94h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
A –
Processor 1
Memory VRD
Hot 2-3
(P1 Mem23 VRD
Hot)
95h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
A –
Processor 2
Memory VRD
Hot 0-1
(P2 Mem01 VRD
Hot)
96h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
A –