Technical Product Specification
Intel
®
Server System R1000SP Product Family TPS 450W Power Subsystem
Revision 2.0 Intel Order Number G64249-002
23
4.4
Power Cord Specification Requirements
Power cords used must meet the specification requirements listed in the following table.
Table 23. AC Power Cord Specifications
Cable Type
SJT
Wire Size
16 AWG
Temperature Rating
105ºC
Amperage Rating
13 A
Voltage Rating
125 V
Figure 20. AC Power Cord
4.5
AC Input Specifications
4.5.1
Power Factor
The power supply must meet the power factor requirements stated in the Energy Star
®
Program
Requirements for Computer Servers. These requirements are stated below.
Output power
20% load
50% load
100% load
Power factor
0.8
0.9
0.95
Tested at 230Vac, 50Hz and 60Hz and 115VAC, 60Hz
4.5.2
AC Input Voltage Specification
The power supply must operate within all specified limits over the following input voltage range.
Harmonic distortion of up to 10% of the rated line voltage must not cause the power supply to
go out of specified limits. Application of an input voltage below 85VAC must not cause damage
to the power supply, including a blown fuse.
Table 24. AC Input Voltage Range
PARAMETER
MIN
RATED
VMAX
Start up VAC
Power Off VAC
Voltage (110)
90 V
rms
100-127 V
rms
140 V
rms
85VAC +/-4VAC
70VAC +/-5VAC
Voltage (220)
180 V
rms
200-240 V
rms
264 V
rms
Frequency
47 Hz
50/60
63 Hz
Notes:
1. Maximum input current at low input voltage range must be measured at 90VAC, at max load.
2. Maximum input current at high input voltage range must be measured at 180VAC, at max load.
3. This requirement is not to be used for determining agency input current markings.
4.5.3
AC Line Isolation Requirements
The power supply must meet all safety agency requirements for dielectric strength.
Transformers’ isolation between primary and secondary windings must comply with the
3000Vac (4242Vdc) dielectric strength criteria. If the working voltage between primary and