Technical Product Specification

Intel
®
Server System R1000SP Product Family TPS Product Family Overview
Revision 2.0 Intel Order Number G64249-002
7
Parameter
Limits
Operating Support operation up to 3050m with ASHRAE class deratings.
Humidity
Shipping 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures
from 25°C to 35°C)
Shock
Operating Half sine, 2g, 11 mSec
Unpackaged Trapezoidal, 25g, velocity change is based on packaged weight
Packaged Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged 5 Hz to 500 Hz 2.20 g RMS random
Packaged 5 Hz to 500 Hz 1.09 g RMS random
AC-DC
Voltage 90 Hz to 132 V and 180 V to 264 V
Frequency 47 Hz to 63 Hz
Source
Interrupt
No loss of data for power line drop-out of 12 mSec
Surge Non-
operating and
operating
Unidirectional
Line to earth
Only
AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Air Discharged 12.0 kV
Contact
Discharge
8.0 kV
Air Flow
Operation Redundant system fan sku 25.6~68.6 CFM
Non-redundant system fan sku 11.3~40.9 CFM
Acoustics
Sound
Power
Measured
Power in
Watts
<300 W ≥300 W ≥600 W ≥1000 W
Servers/Rack
Mount BA
7.0 7.0 7.0 7.0
Disclaimer Note: Intel
®
ensures the unpackaged server board and system meet the shock
requirement mentioned above through its own chassis development and system configuration. It
is the responsibility of the system integrator to determine the proper shock level of the board
and system if the system integrator chooses different system configuration or different chassis.
Intel Corporation cannot be held responsible, if components fail or the server board does not
operate correctly when used outside any of its published operating or non-operating limits.