Technical Product Specification
Functional Architecture Intel® Server Board S1400FP TPS
34 Intel order number G64246-003 Revision 2.0
allows system manufacturers to improve efficiency by using industry available tools to test the
C600 chipset on an assembled board. Since JTAG is a serial interface, it eliminates the need to
create probe points for every pin in an XOR chain. This eases pin breakout and trace routing
and simplifies the interface between the system and a bed-of-nails tester.
3.3.22
KVM/Serial Over LAN (SOL) Function
These functions support redirection of keyboard, mouse, and text screen to a terminal window
on a remote console. The keyboard, mouse, and text redirection enables the control of the client
machine through the network without the need to be physically near that machine. Text, mouse,
and keyboard redirection allows the remote machine to control and configure the client by
entering BIOS setup. The KVM/SOL function emulates a standard PCI serial port and redirects
the data from the serial port to the management console using LAN. KVM has additional
requirements of internal graphics and SOL may be used when KVM is not supported.
3.3.23
On-board Serial Attached SCSI (SAS)/Serial ATA (SATA) Support and Options
The Intel
®
C602 (-A) chipset provides storage support from two integrated controllers: AHCI and
SCU. By default the server board will support two single 6Gb/sec SATA ports routed from the
AHCI controller to the two white SATA connectors labeled “SATA_0” and “SATA_1”, four
3Gb/sec SATA ports routed from the AHCI controller to the four black SATA connectors labeled
“SATA_2” to “SATA_5”, and four 3Gb/sec SATA ports routed from the SCU to the four
SATA/SAS connectors labeled “SATA/SAS_0” to “SATA/SAS_3”.
Note: The SATA/SAS connector labeled “SATA/SAS_4” to “SATA/SAS_7” is NOT functional by
default and is only enabled with the addition of an Intel
®
RAID C600 Upgrade Key option
supporting eight SAS/SATA ports.
Standard are two embedded software RAID options using the storage ports configured from the
SCU only:
Intel
®
Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID SW
RAID technology supporting SATA RAID levels 0,1,10
Intel
®
Rapid Storage Technology (RSTe) supporting SATA RAID levels 0,1,5,10
The server board is capable of supporting additional chipset embedded SAS and RAID options
from the SCU controller when configured with one of several available Intel
®
RAID C600
Upgrade Keys. Upgrade keys install onto a 4-pin connector on the server board labeled
“STOR_UPG_KEY”. The following table identifies available upgrade key options and their
supported features.
Table 7. Intel
®
RAID C600 Upgrade Key Options
Product Code
Color
On-Server Board SATA/SAS Capable Controller
On-Server Board AHCI Capable SATA Controller
No Key
N/A
Intel
®
RSTE 4 ports SATA R0,1,10,5
or Intel
®
ESRT2 4 ports SATA R0,1,10
Intel
®
RSTE SATA R0,1,10,5
or Intel
®
ESRT2 SATA R0,1,10
RKSATA4R5
Black
Intel
®
RSTE 4 ports SATA R0,1,10,5
or Intel
®
ESRT2 4 ports SATA R0,1,10,5
Intel
®
RSTE SATA R0,1,10,5
or Intel
®
ESRT2 SATA R0,1,10,5