Technical Product Specification
Appendix E: Supported Intel® Server Chassis Intel® Server Board S1400FP TPS
Intel order number G64246-003 Revision 2.0
146
Appendix E: Supported Intel
®
Server Chassis
The Intel
®
Server Board S1400FP requires a passive processor heatsink solution when
integrated in the Intel
®
pedestal server chassis listed below. The Intel
®
Server Board S1400FP
supports up to 95W TDP Intel
®
Xeon
®
Processor.
Table 69. Compatible Intel
®
Server Chassis P4000S family
Intel
®
Server Chassis SKU
System Fans
Storage Drives
Power Supply(s)
P4304XXSHDR Two Fixed Fans Four 3.5'' Hotswap Drive Bay Two 460W CRPS
P4304XXSFDR Two Fixed Fans Four 3.5'' Fixed Drive Trays Two 460W CRPS
If an active processor heatsink is used when the Intel
®
Server Board S1400FP is integrated in
the third party chassis, the airflow direction should be followed as shown in the figure below:
Figure 28. Processor Heatsink Installation